#various
3 messages in this thread
#various — declared parent_msg_num=(none), resolved parent_id points to #(none)
S/B-Any insights on a "Internal Error: HMATH 1 0.000000E+5110ED7:"on a Wyse
386 w/ an Intel above bd?? And I've gotten "invalid Q/S format" again on ATO
w/ a corresponding "error #5 at line 10020; stop in line 20001 of module
ac308 at address 2E99:2186" when I try to run ACLS; Jamie?? Call V.Buerg??
Try to load ATO 5.60?? And lastly, any plans to support a HP "color jet" in
the future??? Tanks… Randy@avcom
#22268-#various — declared parent_msg_num=22268, resolved parent_id points to #22268
Randy, HMATH is indicative of a corruption in the drawing, something like a
negative radius or abnormaly large number like 1.234E98. If you can create a
DXF file from the DWG, look in it to find such numbers and change them.
The ATO documentation says that the error # refers to an error code which is
described in the BASIC manual. My BASIC manual says that #5 is an Illegal
function call, an out of range parameter is passed to a math or string
function(, etc.) Further information on this may be obtained in the IBMCOM
forum by leaving a message about it to one of the authors, in fact, they
request that you do so.
The HP PaintJet is supported by Release 9 (on the DUD – driver update disk).
The IBM Color Jetprinter is also supported. What's a "HP color jet"? A new
model? =SM=
#22305-various — declared parent_msg_num=22305, resolved parent_id points to #22305
Steve-The client says that they get this error w/ several different dwgs on
this one Wyse and the dwgs run fine on other PC's (!?). they tried a new math
co-processor in the Wyse but it still generates the HMATH error….our idea
is that it's hardware related but since they didn't buy the PC from us (!!??)
we don't know anything about how it was set-up or how Acad was installed
or….. Any other thoughts??
Thanks for the quick answers… Rb@avcom