#autodesk config screw-up
3 messages in this thread
I was using rcpadi and rctargp this works, but I run into errors..
{{can't find RC*.EXP} file open error} When I set up like you see
below.. I can't get it to render to any screen… I have a targa 16+
and tconfig for live video in from a VCR. the output is feed to
another VCR and a monitor.
START-UP AUTOEXEC
PROMPT $p$g
PATH
C:\WINWORD;C:\;C:\ALDUS;C:\PM4;C:\WINDOWS;C:\DOS;C:\UTILL;C:\UTILL\NU;C:\XTGOLD
C:\
SCAN;C:\BITFAX;C:\LASERLIB;D:\TPLUS
SET TEMP=C:\DOS
C:\DOS\SHARE.EXE
SET RdPADI=D:\3DS2\DRIVERS\RDPtarga.EXP
VGA_INI
TPLUSTSR.exe
set TARGA=247
TPLUSINI D:\TPLUS\T16.ini
d:\ani\vesa\tseng\tlivesa.com
START-UP CONFIG
DEVICE=C:\DOS\HIMEM.SYS
DEVICE=C:\DOS\EMM386.EXE 8000 RAM
DOS=HIGH
DEVICE=C:\UTILL\MOUSE.SYS
DEVICE=C:\DOS\ANSI.SYS
FILES=18
DEVICE=D:\TPLUS\TARGAP.SYS MD I220
Computer 386 33 8 megs// (2) 140 meg HD(s) svga video with 1 meg..
Dave,
Did your message get truncated? I didn't understand your Config / Autoexec
file.
The information that would be helpful too is the SET statement you
have used to inform 3DS which driver the RCPADI etc. is using. In
case you're running out of environment space, make sure that you
start up 3DS without a batch file. If you have a 3DS batch file, go
through each of the steps manually, and just before you start 3DS,
type SET <enter> and make sure the set commands have been spelled
correctly and aren't truncated.
Dave,
Right off the bat, I see you should be using the RDPTPLUS.EXP driver, instead
of the RDPTARGA.EXP driver. There are also a few statements relating to your
targa board that should mabye be in your Autoexec.bat:
Set targaset=
tmode
targedit
These commands are in my autoexec, in addition to the ones that are already in
yours. They all have paramaters after them. Refer to your Taga+ reference
manual for what paramaters to set for your configuration.
-Brian