#35359From: <David L. Gold>Jun 15, 1993 6:33 PM
Geez, from one problem to another. Now during my HD bootup, I see the following: <unset> <unset> <unset> on my screen. Prior to this, my startup-sequence is as follows: Addbuffers df0: 10 c:SetPatch >NIL: ;patch system functions cd c: echo "Splunge Productions Workbench disk. Release 1.3 version 34.20*N" Sys:System/FastMemFirst ; move C00000 memory to last in list BindDrivers SetClock load ;load system time from real time clock (A1000 owners should ;replace the SetClock load with Date STACK 8000
#35361From: Jim Shaffer Jr.Jun 15, 1993 8:41 PM
Something has stomped all over your clock registers. Use "setclock reset" to fix it. (I seem to remember hearing that only certain versions of the setclock command actually worked in reset mode, but I don't remember which ones.)
#35389From: Vic WagnerJun 17, 1993 3:02 PM
Yup, you've got a problem somewhere with your clock.
#35422From: <David L. Gold>Jun 18, 1993 8:49 PM
Strangely enough, I noticed my clock was off, and reset it anyway. Suddenly, the <unset>-tling problem resolved itself. Thanks though. If you hadn't said anything, I wouldn't have known that reseting the clock was what solved my problem. <Dave>