#61166From: Dan McCoyJun 28, 1992 3:16 PM
This has come up quite recently but having not seen many replies (perhaps they went private) but this morning's ground moving activities in California has accelerated my desires to have one. Can anyone recommend a good UPS? I prefer a non-standby UPS. Any recommendations on a rating suitable for keeping a 3000 and monitor up in action for at least 10 minutes? Thanks a bunch. It's not so much that I'm afraid of total loss of power but when the power dies for split seconds… First time one could actually surf in a pool! 🙂 Dan McCoy – via Whap! and saving money doing it too!
#61177From: Christopher TolmieJun 28, 1992 5:35 PM
Dan, So how was the "surf" in you pool? No cracks here, just curious B^) A buddy called me from Marina del Rey and told me he was on the EQ ride. I didn't know about the shaking since I hadn't turned on the TV yet. It was around 9AM when he called and during our conversation I heard a squealing tone in the background and then the line went dead. I thought, Oh gawd, CA just got nuked! He called back, apparently some overloaded phone system blinked for a sec. Well, maybe this will just release some pressure, but then again….better get some large spring mounted platforms for your Amiga. Chris
#61525From: Dan McCoyJul 3, 1992 12:46 PM
The shaking was rather fun. Walking to the hallway was like walking on moving platforms in a fun house. I'm south of both quakes and no damage I can notice around here (though the AC line seems flaky lately). Seeing the backyard flooded with pool water was a site. What is sort of unnerving is the fact that these two quakes' faults form a triangle right to CA's major fault that hasn't released great pressure in a while. Regardless, it's part of living in California just as other natural events happen elsewhere. I just mind it when they disrupt my Amiga sessions! 🙂 Dan McCoy – via Whap! and saving money doing it too!
#61544From: Christopher TolmieJul 3, 1992 7:32 PM
Nothing worse than having an earthquake disrupt a ray trace! It's the pits! B^) Chris
#61586From: Black Belt SystemsJul 4, 1992 12:29 PM
It's the pits? What a nasty crack. I think it's all your fault, too. You need a good shaking – in fact, you should quake in your boots at the thought of such a tremulous pun. :^))) –Ben
#61594From: Christopher TolmieJul 4, 1992 2:19 PM
Ben, Ha Ha! I never thought I was making "…such a tremulous pun…" when I said "It's the pits!". But now that I re-read it I can see that it could crack someone up who has been shaken not stirred just recently. B^))) Chris
#61659From: Dan McCoyJul 5, 1992 12:58 PM
And it flew right over my head! Either I'm drinking too much Mountain Dew or not enough! 🙂 I wouldn't mind seeing an unnamed fault be given the name "My" or "Your". 🙂 Dan McCoy – via Whap! and saving money doing it too!
#61207From: Paul WrightJun 29, 1992 12:47 AM
A year or so ago PC Magazine did an UPS issue. Best buy was a Smart UPS 400 which sits between your monitor and system unit. I know they were reviewing for IBM but electrons are (more or less) electrons. Around $300 I think. The review is useful for its logic even if you do not agree with final conclusions. Related but different… Do you realize that (according to several articles) MOV based surge protectors are only good for about 6 months. Microspikes that don't trigger them reduce them to uselessness quite quickly. Basically, if you read the literature, your computer cannot survive the local environment for more than a few months. That last game of lemmings you played was a figment of your imagination. Actually, the screen never even lit up. —–Paul—-
#61526From: Dan McCoyJul 3, 1992 12:47 PM
Thanks for the info. The info about MOV based strips was news. I do have a Tripp-Lite 1200W line conditioner prior to the computer. It has kicked in now and then over the past four years and for a while, I thought it was giving up the ghost. Turns out that ever since our last earthquake, the AC line house-wide has been screwy. Line conditioners don't do squat for total AC loss though. 🙂 Let your imagination run wild! 🙂 Dan McCoy – via Whap! and saving money doing it too!
#61702From: Paul WrightJul 5, 1992 10:06 PM
The best article I saw on the faults of surge protection was in a MAC magazine of about a year ago. Basically (and oversimplified to the point that I think I understand it) the little microspikes fry the tiny junction point in the MOV that does the switching. Doesn't keep it from working, just slows it down by a few silly microsecond. You need a well equipped laboratory to detect the difference. Unfortunately your motherboard knows the difference in a real lightning spike. There are Surgers that work on different principles but cost better than $100. The article also went into gory detail about how, even when your surge protector works right, it will cause nasties to run back up the ground line into your modem and into the motherboard. Not quite as scary as AIDS but more likely. Sleep well. —–Paul—-
#61883From: Dan McCoyJul 7, 1992 8:49 PM
Thanks for the info. Not sure what kind of protection the TrippLite 1200W line condition has but for the many years I've used it, about the only thing I notice anomalies are during total power failures. 🙂 Although I don't have a o'scope to hook up to the AC line, the system has been happy and I hear the line conditioner kick in often lately (ever since the quakes). Sleep well? 🙂 Thanks again. Dan McCoy – via Whap! and saving money doing it too!
#62110From: Paul WrightJul 9, 1992 11:33 PM
Asbestos I understand it, your UPS will protect you well against brownouts, high voltages (a friend of mine wondered why his lightbulbs never lasted. turned out his house was getting >124 volts. power company said it was a long line and those at the end were barely getting 110.). Spikes may still hazard you, but not as much as the totally unprotected. Shucks, if you have years of experience, it's time to replace your computer anyhow. &) ——Paul—–
#61250From: ShraddhanJun 29, 1992 7:49 PM
Dan, Somewhere on your 3000 (or its power supply – I wish _I_ had such a beastie) there should be an indication of its power consumption (either watts or VA). Add to this the watts or VA rating of all the other equipment you want to have supported by your UPS. This will give you the rating you need. Actually, adding the VA totals together will give an exaggerated estimate, but don't worry about it. A VA value is equal to or greater than the actual power consumption (watts). With all the thunderstorms we've been having here lately, I'm tempted to buy and UPS myself. Regards, Shraddhan – via Whap! from Hertfordshire in the UK
#61397From: BILL LEACHJul 1, 1992 7:56 AM
Shraddhan; While some UPS's may have a "wattage" rating, all UPS's are limited based upon VA. Most UPS makers recommend adding the VA rating of all connected devices and then multiplying by a factor to ensure excess capacity. -bill
#61485From: Christopher TolmieJul 2, 1992 8:25 PM
Hi Bill! Whatcha been doing these days? Haven't seen you in the forums much. Speaking about UPSes, I believe the one someone wanted info on was the type that are in use all the time, not just on standby waiting for low power or a loss of power. You know what I mean? The type that are inverting the battery power to an AC sine wave voltage and powering the computer & peripherals besides charging its battery. Chris Don't be a stranger.
#61517From: BILL LEACHJul 3, 1992 9:06 AM
Hey Chris; I have noted that you are around a bit more lately (of course maybe I'm around a bit more to notice). Been really busy. Will have to teach some classes in Fla. later this month and do not have the course materials finished yet so will be working almost continously for the next few weeks. Had a lightning hit last week. Took out three phones, my stereo and maybe a toaster oven (not certain that the toaster oven was a lightning induced failure). To my shock and amazement the modems that were between the phones and phone line (lost one phone line completely) survived. So did the operating computers! Well back to work — just got a help call from the office. -bill
#61543From: Christopher TolmieJul 3, 1992 7:31 PM
bill, I hate it when lightning strikes! I get nervous every time it begins to storm. Sorry to hear that you lost so much electronics. Lucky that the modems didn't fry. The last time I got stung it took the modem and answering machine, and the submersible well pump! I should be around here a lot more from now on, I really missed my daily (hourly?) CIS fix. Chris
#61527From: Dan McCoyJul 3, 1992 12:47 PM
Tanx. From what I would like to keep up, 400VA should do the trick. Outta be fun computing while the lights are out. If nothing else, I'd still have a clock to look at and reference when resetting all the blinking 12:00 clocks! 🙂 Thunderstorms are another matter. I don't mind total power distruption but DO mind lightning strikes! Dan McCoy – via Whap! and saving money doing it too!
#61679From: ShraddhanJul 5, 1992 6:28 PM
Dan, Out of curiosity, could a UPS inform the computer that external power had gone off, and tell it to shut down gracefully? We've been having a lot of thunderstorms around here lately, and they make me _very_ nervous if I'm using the computer. 400VA seems about right to me. Regards, Shraddhan – via Whap! from Hertfordshire in the UK
#61703From: Paul WrightJul 5, 1992 10:06 PM
UPSes that are intended for LAN use usually have a circuit to notify the LAN to shutdown gracefully. Of course the computer has to be running some kind of background process to see and react to the signal. —–Paul—-
#61982From: ShraddhanJul 8, 1992 5:21 PM
Paul, So the computer runs a background process looking for a signal from the UPS. Hmmm, so if I had more ports on my computer… No problem. Regards, Shraddhan – via Whap! from Hertfordshire in the UK
#62111From: Paul WrightJul 9, 1992 11:33 PM
Yeah. Don't remember any special port. I think it comes in the serial port. May be wrong though. I'm not running a LAN and it seemed somewhat esoteric. =====Paul=====
#61882From: Dan McCoyJul 7, 1992 8:49 PM
Some UPS systems have a serial interface that you could plug into the computer. You could write a program (or ARexx script) that keep checking the port now and then to check the status and act accordingly. Of course, some programs you just can't stop by telling it to without being there… Thunderstorms are a different beast. Since I don't live in an area that gets hit by thunderstorms that often, I'm not versed on how well such systems would protect you (though I am interested). The building where my mom works got struck by lightning a few months back and toasted a board or three even with protection. Egads! I DO know that the line conditioner I've used for almost four years has saved my butt several times… 🙂 Dan McCoy – via Whap! and saving money doing it too!
#61933From: Black Belt SystemsJul 8, 1992 1:24 AM
Dan, In most cases, that "serial interface" is no more than a single RS-232 level line which the manufacturer suggests you connect to the "carrier detect" line of a serial interface somewhere – wasting all it's other lines, just incidentally – the system software watches for an active carrier detect indication from the serial port and if it sees that, it does (whatever) because it knows power to the input of the UPS is now gone or below spec (usually below 103 vac or above 130 – or gone, of course). A small bit of custom s/w would have to be written to deal with this methinks. We may do it; we'll be heavily UPS'd before too long, and the units we've chosen will have that serial capability. The only reason we might NOT do it is because I've not yet been able to think of anything to do with the information that wouldn't involve hacking the OS one way or another. Protection from thunderstorms is one of those knotty questions. If you get a direct lightning strike, by which I mean on YOUR power line, past the power company's xformer, odds are good that all your "protective" devices may have to be extracted from the walls with crowbars after they hit them at near supersonic speeds – in pieces. :^) Surges from strikes further down the line can be taken care of to some degree by MOV's and other semiconductor arcanae, which are used in power strips and (almost always) in UPS units. Certainly in good UPS units. It is well to remember that lightning can enter a computer system via the modem's telephone line, inductively through cables lying about on your floor (assuming a VERY near strike, like outside the wall where the computer is), through computer controlled equipment like musical MIDI gear, HAM radios, video gear->television antennas/cable, the power line, weather stations like my heath ID5001, and so on. It's sort of like sex. The best protection – don't plug it in. (Running away). –Ben
#62100From: Dan McCoyJul 9, 1992 10:16 PM
Thanks Ben. If this "serial interface" is nothing more than a RS-232 level line, one could reduce the voltage down to TTL level and plug it into the joystick port, eh? GPI trigger type deal. Although I'm not that concerned about a serial interface because, like you said, having the ability to force all tasks to stop would require a OS hack of some sort. I just want one that beeps wildly at me so I can do the turning off. 🙂 Could have used a UPS last night and most of today. Ever since the earthquakes (though it may be a coincidence) we had around here last week, something fishy was going on with the house's AC line. Last night, just when you need the air conditioning the most, we lost power to most of the house. Turns out that the 2 awg wire going from the 100 amp circuit breaker to a terminal for the power meter that supplied the power to these newly dead circuits decided to take a smoke. Mostly charred remains of the terminal block, as it had broken free from the power meter connection. It took the air conditioner to finally break it. The lights and the line conditioner before my computer were having fun during the "am here-am not!" split second phases until it finally gave way! All better now! 🙂 Thanks for the info. Dan McCoy – via Whap! and saving money doing it too!
#62125From: Black Belt SystemsJul 10, 1992 12:24 AM
You're welcome. Certainly you could translate the RS232 level to TTL (or anything else, like a contact closure) without too much effort, if you're moderately familiar with electronics. btw – most of these UPS's do beep rather annoyingly. :^) –Ben
#62133From: Mike SchillerJul 10, 1992 1:08 AM
Dan: I don't think you'll really need a utility to beep at you. With most of the UPSes that I've seen, and specially the one here on the Amiga, and the one on the PC's at the office have this really loud, really obnoxiously high pitches beep that will wake the dead so they can powerdown the machine! -Mike Schiller In sunny Fort Lauderdale
#62142From: Don Curtis/SYSOPJul 10, 1992 2:50 AM
Mike, Beeping machines and UPS'es presume that there is someone there to hear it. Autoshutdown software hooked to the UPS is far more reliable <grin>. Don
#62145From: Mike SchillerJul 10, 1992 3:43 AM
Don: I realise that, but the person mentioned that all they'd want to do was write a program (or script) that would beep when the UPS was active (a power failure). In that case, it really wouldn't be needed. As for auto shutdown software, yes I agree with you, now if there was only such an animal for the Amiga! -Mike Schiller In sunny Fort Lauderdale
#62230From: Brian CowanJul 11, 1992 2:50 AM
Well, If the programs running supported ARexx, wouldn't it be possible to send all open ARexx ports a "Quit" message? Brian – via Whap!
#62206From: Paul WrightJul 10, 1992 11:06 PM
Yeah, but the hourly wage for a dead tech would be affordable. —-Paul—-
#62229From: Brian CowanJul 11, 1992 2:50 AM
Well, if you're dealing with the APC "Back-UPS," they claim that their "On Battery" amd "Low Battery" indications are nothing more than switch closures. If so — and I'll find out when I get mine in — I think wiring something into the second joystick port will be childs play. If not…. Where did I put those optoisolators? Brian – via Whap!
#62015From: Malcolm O'BrienJul 8, 1992 11:02 PM
Shraddhan, There's a UPS specifially for Windows! When the power goes, you can open a window and see a graph that shows when the power drop occured. A most unusual product. Malcolm
#62084From: ShraddhanJul 9, 1992 7:25 PM
Yes, sometimes it seems that those IBMers have everything… I would imagine that a more useful facility would be the ability to maintain an automatic log of power ups and downs. Regards, Shraddhan – via Whap! from Hertfordshire in the UK
#62126From: Black Belt SystemsJul 10, 1992 12:24 AM
Also my thought. –Ben
#62231From: Brian CowanJul 11, 1992 2:50 AM
APC Smart-UPS…. We have 2 on our PC LAN at work. It — in conjunction with the server-resident software, does that and monitors line sage, performs regular UPS tests, etc., etc. It talks using a standard serial connection, and the company charges a fairly low price for the documentation so that you can make your computer speak the UPS's "Language." Brian – via Whap!
#62304From: ShraddhanJul 11, 1992 8:34 PM
Brian, Thanks for the info. >> the company charges a fairly low price for the documentation… I'm rather surprised that they charge at all! Regards, Shraddhan – via Whap! from Hertfordshire in the UK
#62386From: Brian CowanJul 12, 1992 1:48 PM
I'll bet _they_ licenced the controller's language from someone else, and because of this, decided to charge others for the docs too. Also, let's remember that, until recently, UPS's have been primarily the domain of corporate customers who could easily deal with paying for the programming docs. since all of their UPS's Seem to use "contact closure" as another means for informing the host (client?) computer that power has died — and this _is_ in the user manual (or so I'm told) — most users can use this information and not deal with the Smart-UPS's more oddball features. Brian
#62521From: ShraddhanJul 13, 1992 4:03 PM
Brian, Sounds to me like a way of getting more money out of the customer. Also, I suppose many customers wold think more highly of a product if it was "well supported" – i.e. if you have to pay for the information you think you might need to use it. I really fail to see what kind of language would be needed to transfer one or two bits of information – i.e. power on/off, battery OK/low – when a couple of contact closures would do. Regards, Shraddhan – via Whap! from Hertfordshire in the UK
#62648From: Jay TruesdaleJul 14, 1992 8:07 PM
APC charges, I think, $50 for the documentation as to what comes out of the serial port of their UPSs. BEST, another UPS manufacturer, will send you the information about their serial port in the form of a "Tech Note" for free. Which unit do you think I'll buy? With the information from Best, it should be possible to draw some pretty nifty charts and diagrams using the UPS data just like on those PC-Klones. On a related note, Don't you just HATE explaining to people that you have no intention of using their product with a "PC Compatible" and that is why you can't run their nifty canned program and that is why you need detailed technical information? (sigh!) -J
#62316From: Malcolm O'BrienJul 11, 1992 9:48 PM
Shraddhan, I believe that it does do the logs for you so you can show your grandchildren the history of your electric company. 🙂 And it'll also shut down Windows for you before dropping out entirely. Malcolm
#61284From: Brian BartlettJun 30, 1992 3:20 AM
Dan, I'd have to recommend the American Power Conversion Back-UPS 450AT. I'm using the here for my accelerated 2000, monitor, and modem. It's held up for at least 25 minutes on two occasions so far. I wish these aftershocks would stop! Brian Bartlett