#67102From: Michael SternbergSep 24, 1989 4:00 PM
I've used DrawPlus a fair amount for piping plans and a few pre-rearrange the living room drawings. Go ahead and describe your difficulties a bit more and I'll give it a go.
#67130From: Joanne BandlowSep 24, 1989 9:12 PM
Thanks. Well, it seems when I use the "drag it" tool to move something just a pinch, the program draws the object in a different place than the shadow'ed outline says it'll do. I was trying to arrange an equipment rack layout, and it was maddening…. each time the result was different, but never right. Sometimes it wouldn't move the object at all. The other problem – I've found, through experimenting, that if I try to send a drawing to my plotter directly, parts of the drawing will fall off the edge of the earth, and the plotter will freak. But if I plot to the DRAWPLOTDUMP file, then type > par: the file to the plotter thru the CLI, it works just fine. A timing error or something? The plotter is using the Centronics parallel interface. The plotter's self-test works fine. I dunno. Thanks for any help you can offer. -joanne
#67162From: Peter SmithemSep 25, 1989 7:16 AM
Sounds like you have grid snap turned on. Toggle it off and you should be able to put objects down where ever you want to. Can't help with the plotter. I haven't used one with Draw2000 yet. I've been sketching vector graphics for a digital scope at work and output through a custom plotter driver to disk which is compiled into instructions for the vector display processor. Sure beats sketching them out on paper. The only output problems I've had is trying to dump to a dot matrix printer. Guru's every time, but it's something about the way my system is set up that's causing that. It worked fine on another system. Peter_S (LeCroy Corp)
#67181From: Joanne BandlowSep 25, 1989 11:49 AM
Sounds like you have a nifty system. Sorry I forgot to mention it, but grid snap WAS off. I also found some problems with grid snap, but that's another story. On your printer Guru'ing, do you perhaps have the new prefs printer drivers mixed with the old printer.device? I seem to recall getting Gurus in Dpaint until I caught that….
#67362From: Richard Rae/SYSOPSep 26, 1989 11:07 AM
If grid snap was off, I can't imagine what was happening. You know how it is, though; if one of us could SEE it, we'd probably go "AH…" and tell you what's up. Doing it "verbally" like this makes it tricky until something "clicks" for one of us. Do keep us up to date. Regarding problems, there are a lot of sneaky problems hiding in Draw and Draw Plus. For example, you can select "Part" from the menu and it will work fine, but if you select "Part" from the keyboard combination, Draw will insist "Part Not Found". Until you learn to work around the problems and limitations, it can be really frustrating. (In all fairness, once you learn how to do that, it's a reasonably powerful package that does probably 95% of what 95% of us need.)
#67426From: Joanne BandlowSep 26, 1989 7:58 PM
Yeah, I know what you mean…. you really have to see it for yourself to have it 'click.' If I find any more outstanding clues, I'll let you know. Thanks for the help.
#67186From: Richard Rae/SYSOPSep 25, 1989 1:38 PM
Peter sounds to be bang on with his comments about grid snap. For something like an equipment rack where you want fairly exact placement, just turning off grid snap may be even more frustrating, though! A couple of things you might try. Zoom way in on a corner of the object you want to place and try it there. As you zoom in, Draw resizes the grid so that you still have a reasonable resolution; this means you'll be able to get closer than you could before. If you prefer to work with grid snap off, try turning data snap on. This snaps you to the nearest data point. For example, if you wanted to place two boxes side by side, you would grab the corner of one box and deposit it near the corner of the other box. Draw will take the data point which represents the corner of your box, and will align it exactly with the nearest data point it can find: the corner of the other box. Also, turn your grid on if it isn't; this may help you visualize exactly what's going on when things aren't placed where you think they should be.
#67276From: Joanne BandlowSep 25, 1989 8:54 PM
Well, I zoomed in as close as I could to place the objects (I've been here before) when I encountered the problem. I'll give data snap a try… thanks!
#67471From: Michael SternbergSep 27, 1989 1:08 AM
Re the Plotter….what mfr and model? Secondly…was the object being 'dragged' a part? If so, is it the same scale as the drawing format? If so, is grid lock on or free? We'll get this figured out….you betcha!
#67560From: Joanne BandlowSep 27, 1989 8:44 PM
The object was a rectangle containing a text label within, grouped as a part. I was attempting to line it up in a drawing of a vertical rack. Same scale for everything, grid & data snap off. I haven't tried data snap on yet, but grid snap caused 'overshoots' at times. The plotter is a Comrex Comscriber II (really made by someone else… it uses Roland DXY 800/101 codes) though I haven't been able to track down anyone who admits to making it… I've even called Japan! The plotter is a 4-pen flatbed, 11×17, parallel input. It also uses an unusual pen holder, an adapter which resembles an HP pen but with two flanges instead of one. The adaptor holds a Pentel Ceramicron refill pen, which is only available for paper media (another problem, as I'd like to plot on acetate sometimes).
#67264From: Ray LewisSep 25, 1989 8:42 PM
Excuse me for jumping into the thread, but I dl'd a shareware cad program which says it can save files in DrawPlus format, and that this is compatible with a number of other programs. Does the DrawPlus format have another name (for example, is it HPGL, or AutoCad ????) As you can tell from my question, I am a complete novice re cad programs.
#67363From: Richard Rae/SYSOPSep 26, 1989 11:08 AM
I don't think DrawPlus's internal format is anything but proprietary (but that only means I haven't heard otherwise!) If you need a standard format — for exporting, perhaps — you can get HPGL by playing a little trick. When you select PLOT, DP creates a drawing file which it then spools to the plotter (I believe the name is DrawPlotDump). If you will take your printer OFF LINE (because DP uses the printer.device for plotter output) and then request a plot, it will create the file, then try to write to the printer, throwing up a requester. Cancel the requester and you have an HPGL file just waiting to be used! (Of course you can't import in this manner.) If you're willing to do some work, you can also build a specification file which causes DP to "plot" in any format you need… so you could conceivably create an AutoCAD file directly. But it'd take quite a bit of setup the first time.