#127300From: Stephen D PidgeonOct 5, 1994 1:06 PM
Upgrading hassle: Added a PAR to network and upgraded to Lantastic 6.0 Incident: PAR operates correctly for the exception of importing .TGAs from any drive when the network is up. It will import the same files it gave corrupt or incompatible error messages for from it's own C: drive, when the network is not up. This happens with both the beta 1.27b and the shipping version 1.09. Objective: 1. Fix the import problem with the PAR so importing can be from any network drive using PAR software. 2. Develop a technique where files can be copied to the PAR drive from any network drive using DOS commands, and resulting in an .ANI. This technique if possible, will bypass having to run PAR and use IMPORT command. Item 1 is critical, Item 2 is wishlist. Steve Pidgeon Pulse Productions Tampa, FL pidgeon@gate.net 70732,2546 813-977-8414
#127345From: Gus GrubbaOct 5, 1994 5:43 PM
I saw your not over the mail list! I'm not sure I understand all of your problems. Alan Iglesias has the same setup you do and he could probably have more answers than I do. The DPS dude with "all" the answers is also around. His name is Brick Eksten and he has been a great help. It seems to me you have a conflict among your software configuration. I don't use Lantastic so I can't say much about it. Also make sure no two (or more) systems are writing and/or reading to/from the PAR at the same time. The driver is not multitasking.
#127398From: Jeff RichardsonOct 5, 1994 11:46 PM
Stephen, I am currently running PAR (1.27b) along with Lantastic 6.0 and don't have any problems reading network drives from the PAR software. You have to be sure to load your network software *BEFORE* (yes, before) you run the PAR drivers. Oh, and set up the PAR as an "OTHER" network drive in your Lantastic Resources. The network access capabilities of this drive should be "RWC-L——-". I've even had limited success allowing slave machines reading the PAR drive for rotoscoping. You can install your PAR as a network drive. The problem I was having was that while the slave machines are reading the PAR, the machine where the PAR was installed would have some sort of "lockup". I couldn't do any work with the machine where PAR was installed, but the slave machines could continue to read the PAR…..kinda weird. I read another message here indicating that the PAR software is not multitasking and so wouldn't work with multiple machines reading it. This may be so…..and my experiment mentioned above may have worked just by fluke, that none of the slaves attempted to read PAR at the same time. Later, -Jeff
#127461From: ALAN IGLESIASOct 6, 1994 10:04 AM
Hi Steve, My system is set up the way JeffR has described (second paragraph) in his message to you. The PAR software sees networked drives no problem. If you'd like to talk about this over the phone, let me know and I'll Email you my number… -Alan
#127496From: Stephen D PidgeonOct 6, 1994 1:03 PM
Hi Alan, Yes, I'd like to persue this. I haven't put much time in it so far, just set it up and had a problem. Took no time at all to create this situation 🙂 I'm using an NE2000 clone set at IOBASE 300 and INT 5. I'd be grateful if you could shed some light on configuring the PAR dedicated drive as a resource. My initial attempts result in a message that says the drive has no volume label, and the next message is one of those Abort, Retry, Fail messages. Other than that, it would be good to hear from you. Still thinking/saving for LA95. Gus suggested that I follow-up with you since we are running similiar systems. My item 2 is also of interest to me….copying TGAs to the PAR drive using DOS commands….are you having any success doing this? BTW, Lee tells me you were very helpful in his initial attempts with FLAME. Steve
#127724From: Stephen D PidgeonOct 7, 1994 12:32 PM
Alan/All to replied, This is like Burger King…..'I love this place' The solution to my problem was provided by Alan …. Thanx Alan. The solution (FYI) In autoexec.bat launch parint, then call startnet.bat, then launch pardrv. In Lantastic Net_mgr, set PAR drive as other Voila! It works. I guess that it says to do this somewhere in something but I didn't find it. Thanx for the always beneficial support we get here. Steve Pidgeon Pulse Productions Tampa, FL
#127769From: ALAN IGLESIASOct 7, 1994 5:12 PM
My pleasure, Steve… -Alan