I have an AutoCAD operator whoa has been experiencing problems on his wo
workstation running AutoCAD r11 c2. When inserting blocks or blocks with
attributes the block appears to be "ghosted" on the screen and doesn't
appear until he does a regen/redraw. Also the attributes do not appear
until the same is done. If he changes the attribute values, the changes
won't appear until he does a regen/redraw. Someone suggested that this was
because REGENAUTO was off. Turning REGENAUTO on didn't seem to help. I
experimented with the ATTMODE variable as well and that didn't seem to help
either. Any ideas or help would be appreciated.
Thank-you 🙂
Mario – I've never heard of this one… as was mentioned earlier (maybe on
the VAUS BBS), there *was* a problem with displaying blocks in one of the
earlier Release 11s, but it was fixed by 11c2.
Any chance you could upload one of these blocks for someone here to look at?
If so, post it in Lib 9 "What's New" and indicate in the file description
that it's for the sysops to check out an attribute visibility problem.
Dave