CompuServe Messages

V32.bis modem

    12-Jun-92 01:16:13
Sb: #59768-V32.bis modem
Fm: Supra Corp 76004,565
To: Patrick Langer 100013,1277
Patrick >I encountered several problems: The *H option won't work. The Modem >responds with ERROR. Is this bug unique or have others encountered it? There is no *H along with several commands that have to do with MNP10. RockWell was unable to implement MNP10 like they thought they would, and we had already wrote the manual based on the idea it would be there. >While looking at the display of the settings done with &v, I found several >commands and registers which are not described in the manual: %Gx, S44, S49, >S50. The %G is new, it turns on the fall back feature of v.32bis. The s register setting I'm not sure about. None of them exist, I'm not sure why the modem is displaying them. I think maybe a bit got shifted, because they are all off by a power of two I think from the actually commands. I will check on this tomorrow. Your friends disconnects sound like line quality problems. With the fall back/forward feature which is just now being implimented these problems should go away. That is alot of the reason for the July 15 ROM upgrade. Kenny Supra Tech Support