Fm: Sysop larry gensch 72236,3516
To: FRANK GAGLIARDI 74716,37

This message turned up in search, but its forum couldn’t be identified from the original transcript, so it may not be linked into its thread.

Your best bet on information on interfacing the Model 100 is the Service Manual (R/S Catalog Number 26-3801/3802). The easiest ports to use are: Cassette Relay (Use BASIC "MOTOR ON" AND "MOTOR OFF" to turn it on and off) BAR CODE Port – For controling serial devices RS-232 Port – For serial devices Sears, Tandy, and BSR sell controllers that allow individual AC devices or Lamps to be turned on and off; although this system can NOT tell if a given device is on or off. I use this for a sort of burglar discourager (it shuts my lights on and off randomly at night when I am not home). Computer controllers are available to interface with computers. Let me know if you need more information.