Timesaver it ain't
19-Jul-87 21:24:37
Sb: #76936-Timesaver it ain't
Fm: Greg White 72105,1616
To: Greg White 72105,1616
CONTINUED FROM #76963
5) All I can say about ATime is how it acted for me. From what I have read
about ATime is that at bootup ATime is activated and waits to be interrogated
by either READ-RTC or SET-RTC. If neither of these is used (as in booting with
Deluxe Paint) then ATime stays active, waiting to be read or written to. The
first time I would print a picture with DP then ATime would get the picture
data and usually reset its time with garbage. At this time ATime would drop off
the line and data would continue to the printer. However since ATime seems to
have intercepted the first data then the printer did not get the setup data and
instead of a picture I would get garbage. If I aborted the picture and tried
again, then all was OK as ATime was offline. This did not happen if ATime was
disconnected. I had a early ATime and maybe this was corrected in later
versions. I do know they had several versions, i.e. time calibration, no time
calibration, usable with Genlock, not usable with Genlock. All I can tell you
is how mine acted and why I did not like it. I also like things I buy to work
and I find TimeSaver works where ATime doesn't. That is what I bought it for.
Since we are apparently comparing credentials, I am a Consulting Engineer
(Hardware and Software) for a NASA contractor here at Johnson Space Center in
Houston. Presently we are using several Amigas to develop a computerized
interactive exercise facility for the Space Station.