SERIOUS Newtek Concerns
12-Jul-94 21:30:56
Sb: #86104-SERIOUS Newtek Concerns
Fm: steve mackie 70714,1567
To: Joe Maulucci 70702,230
You should not remove safety grounds from equipment, it's unsafe for
the operator, in some cases it can increase the equipment's susceptibility
to R.F. and it's illegal (the SGP [safety ground police] are everywhere!)
I think Newtek offered a way of trouble shooting and identifing the
source of the interference, not a solution to it.
The "ideal" audio system ground would be a "star" or single point
ground system where each piece's analog signal ground goes to a centrally
located copper plate (insulated from any other ground) which in turn has
one wire to the AC ground (waterpipe). Then each of the chassis grounds
(safety ground) goes to the AC outlet. All input and output cable shield's
are left floating (disconnected) at the receiving end. (I'm not so sure
about applying this floating shield idea to higher frequency video signals
and I'm not to crazy about hackin-up all my cables)
Those of us who don't have equipment with a "floating" (seperate from
the chassis) analog signal ground, must rely on the third wire safety
ground connected to one isolated ground recepticle (seperate ground wire
to AC ground/waterpipe). This, I believe, is the way Jerry hooked up his
system (chassis ground wires, in a "star" configuration, to one outlet –
then to the ground rod).
All this talk about ground loops had me searching thru stacks of stuff
to find my secret SGP file on grounding – (access on a need to know basis
only!)… I found it! So for anyone that's interested here's a list of
info sources:
A CLEAN AUDIO INSTALLATION GUIDE, by A. Burdick,Benchmark Media Sys. Inc.
5925 Court St. Rd., Syracuse, NY 13206
WIRING AN AUDIO-VIDEO PROD. FACILITY, by E.Howard, Broadcast Eng.Mag. 9/86
GROUNDING AFFECTS NOISE & SAFETY, Sound Info Series data sheets by Yamaha
Corp, PO 6600, Buena Park, CA 90622
WHAT'S ALL THIS GROUND NOISE STUFF, ANYHOW?, by B.Pease, Electronic Design
Mag., 6/24/93, pg.70
ELIMINATING NOISE: A HUM-BLE LIMERICK, by Peter Utz, AV Video Mag, 6/92
North Hills Elec. Inc. (516-671-5700) offers several video isolation
transformers which can be used to eliminate ground loop problems.
Isolation transformers work if you know the source of the problem. I used
a home made one to solve my cable TV gremlin.
Smac @;-^D 70714,1567
ICA service Inc.