Andy,
Things are quiet here aren't they? It is a bit louder over on Internet, where
there is a HyperChem email users' group.
Anyway, I made up a while ago two scripts that do what you want. I just tried
to upload them into the libraries, but apparently there is no space there, so
let's see if they'll fit into a message.
Here goes:
; saveir.scr ;=========== ; Save the existing IR spectrum. This script ;
produces or writes over the file "\hyper\chem_ir.scr" ; which can be run later
to recover the IR data. ; ; When running chem_ir.scr to regenerate the spectrum
; you must first have the appropriate molecule on the screen.
query-response-has-tag true omsgs-to-file \hyper\chem_ir.scr status-message
"Saving IR spectrum to \hyper\chem_ir.scr" ;Save computational procedure used.
calculation-method ? semi-empirical-method ?
;Save semi-empirical options. quantum-total-charge ? multiplicity ?
scf-convergence ? max-iterations ? accelerate-scf-convergence ? uhf ?
excited-state ?
;Save spectrum ir-band-count ? ir-frequency ? ir-intensity ?
ir-intensity-components ? ir-normal-mode ? vibrational-mode ?
status-message "Spectrum saved"