#floptical problems
01-Nov-93 09:10:14
Sb: #120364-#floptical problems
Fm: BILL LEACH 71330,2621
To: Paul Wright 74135,1044
John mentioned something that is very important… termination.
Each end of the physical scsi bus should be terminated and no other
termination should exist.
Have you "changed drive type" to get the drive characteristics set in
the RDB? Have you partitioned the drive?
I would not necessarily worry too much about the lowlevel format.
You actually don't lowlevel format most scsi drives anyway. Have you
tried to DOS format the drive (from Workbench or CLI)?