A3000 Help, Please
17-Dec-92 09:02:12
Sb: #81589-A3000 Help, Please
Fm: BILL LEACH 71330,2621
To: Steven D. Kapplin 70055,1021
Steven;
Replying to your message to Mike….
The failure to boot with Konica powered off sure sounds like either: the
A3000 terminator power diode is installed backward or the MacSCSI cable is
bad. While I personally have not had a bad MacSCSI cable (and I have
about a dozen), I have talked with quite a few people that have had.
Other possible problems: the Konica might not have a terminator power
diode at all, and no auctioneering circuit for terminator power (this is
likely if the Konica is not designed to share the SCSI bus).
—————-
The boot delay is just something that you will have to learn to live with
unless you re-order the scsi addressing and set the "last drive" bit on
the internal drive.
—————-
Again, the motherboard is what should not be terminated when using both
internal and external drives.
—————-
Have a good trip!
-bill