Overscan
Help, does anyone know how to handle "overscan" mode such that you can
still effectivly use intuition windows on the screen. I have gotten the
screen to overscan by changing screen.ViewPort.DxOfset and DyOffset and
then doing a RethinkDisplay(). This seems to work fine unless I want the
user to be able to use the mouse. When you open up a window on a screen
like this the top of the window will start at the top of the screen, but
the left side of the window starts at the normal palce. Also intuition
thinks that everything is where it would be if I hadn't messed with the
screen. This means that I have to click BELOW where I normally would.
The Amiga documentation for "overscan" is not very good and I was wondering
if any of you had a clue on how to do it. Thanks, -BOB- 🙂