Jim,
I have the NEC 3xe's DIP switch set to SCSI-II and it is working. The
cable that NEC supplied had a DB-25 on one end and a 50 pin centronics on
the other. Actually the 50 pin end may not actually be Centronics as it is
very small, not like the size of a centronics printer connector. The
person at the computer store said that although they have 50 pins, at this
time only 25 are actually used. Go figure. Anyone else have additional
info on this?