#186607From: Martin KayFeb 25, 1995 2:52 PM
Anyone happen to have the pin connections for making up a parnet cable? I've looked in the libraries but haven't seen anything obvious, just lots of software. I have the software setup from when I visited someone a while back, who had a cable and connected up to my machine, but I had no need of it myself back then. Now I need to copy from an A3000 to an A1200. Can anyone help? Martin Kay
#186620From: Zeddock MillerFeb 25, 1995 6:04 PM
The parnet DL I have has the pinouts in it. Zeddock Miller
#186656From: Karl F. KugelFeb 26, 1995 3:29 AM
This might help (from the parnet docs): MAKING A CABLE The following connections need to be made on a DB25 cable: You are making a cable that connects the two PARALLEL ports of your Amiga together. CABLE: Connect D7-D0,SEL,POUT, and BUSY across, Connect ACK (FLAG interrupt) to SEL locally: (2-9) D7-D0 ———— D7-D0 (12) POUT ———— POUT (11) BUSY ———— BUSY PARALLEL PORT (13) SEL –+——+– SEL (10) ACK -/ \- ACK (18-22) GND ———— GND (18-22) Double check the gender for the DB25 connectors you will need to connect to your Parallel Port. A500/A2000, Parallel port is Female so you need a Male connector A1000,Parallel port is Male so you need a Female connector. The easiest thing to do is to buy a premade cable with all 25 lines passed and DB25 connectors on both ends (Double check the gender's that they match before you buy the cable!) And then rip it apart and cut-and-seal those wires which are not supposed to be connected. You also need to bridge ACK to SEL as per the diagram above ON BOTH ENDS OF THE CABLE, as shown above. ** NEVER PLUG IN AN UNMODIFIED CABLE BETWEEN THE TWO COMPUTERS! ** DOUBLE CHECK YOUR CABLE BEFORE INSTALLATION! WARNING! INTERFERENCE WITH SERIAL-PORT. The RI (Ring Indicate) line on the Amiga's serial port uses the SEL line to source a transitor. This interferes with the SEL line which, as you can see, is part of the network. Be sure that (a) either no serial cable is attached or that (b) It doesn't connect RI or that (c) your modem doesn't connect RI internally. -Karl
#186779From: Martin KayFeb 27, 1995 12:26 PM
Karl, Many thanks for the pinout info – this was just what I was looking for 😎 Regards, Martin
#186968From: Karl F. KugelMar 1, 1995 1:45 AM
You can thank a large hard drive and Steve Ahlstrom, who made it easy to import documents into Autopilot. <G> And you're welcome. -Karl
#187029From: Ron LegroMar 1, 1995 5:02 PM
Karl, With respect to the RI line interfering with the SEL line… Maybe that explains the following: I have an external modem on serial port and a Migraph scanner in the parallel port. When the telephone rings (voice call, fax or data), the scanner light blinks in rhythm! This has always made me very nervous. But everything seems to work. I wonder what would happen, though, if I was scanning a document when the phone suddenly would ring. And I've never tried scanning while on line with the modem.
#187096From: Karl F. KugelMar 1, 1995 11:14 PM
Could be. This is the first I've heard of it myself, but your experience certainly sounds suggestive. -Karl