I have the Supra v.32bis FaxModem and am having real trouble with it.
Would appreciate any help….
I cannot get a reliable connect with it, on CIS or other boards. I've
tried several com packages: Autopilot, Whap, Online, ATalkIII. When I
try to connect at any speed (well at 2400 or 9600 anyway) I get garbage on
my screen right after CIS or the BBS phone answers and communication is
being set up. Garbage like: '^%34mmmmmm *7((((,,,', etc… Sometimes
long strings of the same garbage character. (remember, this is when I am
supposed to see CONNECT, etc)
A few facts:
1. My old Supra 2400 still works just fine on my machine (at 2400).
(but the new modem won't connect at either 2400 or 9600). This
makes me think it is not the line.
2. My new v.32 modem works on a friend's Amiga just fine, at any
speed. He is running basically the same machine configuration:
— A2000 w/030; WB2.1, etc
This makes me think the modem is working properly.
3. I just received the upgrade ROMS for the modem and installed them,
hoping that would fix things. Nope. Still the same symptoms..
4. I have tried various Serial Prefs settings, including:
96007E1, 96008N0, 96008N1, 24007E1, 24008N1, basically anything
that seemed to make sense. (BTW, doesn't the terminal software
override prefs and set the parameters itself; do I even need
to try other settings?)
5. I have kept the modem at default settings. Manual doesn't
recommend anything different that I can tell.
Frankly, I'm stumped. I'm willing to try just about anything, cause the
new modem is a very expensive paperweight. Help appreciated. Thanks in
advance. –jp–seattle–
John,
I have v.32 also… my initialize string is AT&F2E0.
I call CIS on one of their 9600 numbers with no problem using both
AutoPilot and BaudBandit (F8N1).
I use to get garbage when my software's default settings were different
than what was used to sign on. Although I have ATalk, I never could get
things right … so I am sticking with BaudBandit.
BTW since I missed it, FYI… there's a registration card for the GPFax
software in the manual as a page that you'll need to send in.
Joe Maulucci >>> AP ENGAGED
John,
Make sure your serial preferences are setup for CTS/RTS flow
control.
Don
First of all, try to complete the login even though you can't make out the
words (eg. when you first connect press enter, after the first string of
garbage type CIS enter, next string of garbage – login, then password).
If you are able to get to the password portion and from there on the text
is readable then you need to set your comm program to strip the high bit.
If that is not the problem, try these settings out. They are what I use
and I have not had any trouble.
Baud Rate: 19200 – this number should be higher than 9600 if you are using
MNP or LAPM compression even if you are logging on at 9600 or 2400
8N1
RTS/CTS
Full Duplex
Set up string: AT &F2 L0 M3 T5 – the last three only control timing out
and the speaker so you could get away with only AT &F2
You are right about the comm program normally overriding anything that you
may have set within preferences, so you need to make sure that all of your
changes are made within you comm program.
Bill
PS One last question, what cable are you using?
Try setting your modem setup string to AT&F2
That's what I use.
Steve
John,
Make sure you've got CTS/RTS selected from serial preferences. Also make
sure you modem cable supports those lines (ie., a "7 wire" cable).
-sja
John,
I have a Supra Fax Modem Plus and had a similar problem at the beggining.
It seems the node I reach here didn't support MNP or LAPM or DC. So I had
to type this at the JRComm after it initialized it.
AT\N1 <ENTER> <– Watch the back slash it is "\" not "/"
Then try to make the connection.
If it works try AT\N3 which tries a realiable MNP link.
If it doesn't works, maybe the node you reach can't reach MNP.
Whichever setting works type it (i.e. AT\N1 <RETURN>) and AT &W <RETURN>.
That will save the setting on the modem's non-volatile memory.
Hope this helps.
Jorge Escobar/MEGABYTE PRODUCTIONS (…and AutoPilot, of course!)