Pinnacle RCD Info!!
1 messages in this thread
Hi everybody.
Here's a news flash from Pinnacle for all of my Pinnacle customers (and even
those who aren't my customers) here in cyberspace. If you own or are planning
to purchase an RCD, this is important stuff.
THERMAL RECALIBRATION
Most disk drives (hard drives, optical drives, etc.) perform an action called
"thermal recalibration" every so often. Sometimes this occurs periodically,
and sometimes it occurs after a specified temperature change. It is done more
often by large, fast hard drives. Sometimes, due to the firmware design, this
process causes delays of up to 1 second to the Macintosh system. If this
occurs while you are creating a CD you will get an error "-186." This means
that the internal buffer on the RCD has run dry (personal note: this is …
bad.) If this occurs the CD will be *unusable* (see, told you.) DO NOT try
over and over again. If this happens to you, contact Pinnacle Technical
Support at 714-727-3300 immediately.
Pinnacle has confirmed that most Micropolis hard drives are incompatible with
the RCD for this reason.
SMALL FILES
When performing a file by file copy such as ISO-9660 and HFS the overhead
required to open and close many small files can cause the RCD buffer to run dry
(this, in Ghostbusters terminology is known as "total protonic reversal.")
Again, this will cause the disk to be unusable. Please try to copy only files
over approximately 8K to the RCD.
The current driver software is now version 1.2. Any RCD customer who hasn't
received their copy can contact Pinnacle at 1-800-553-7070 to get their copy
sent to them immediately (of course, my customers have theirs <g>.)
This message is printed as a public service of Mardun Software Ltd., a Pinnacle
Micro dealer.
Sincerely,
Duane Burghard
Mardun Software Ltd.