I have an A2000, 040/28Mhz accel w/8MB, A2091 w/ 2MB. Problem is, my
Iomega Bernoulli 150 Mac Transportable seems to power down the disk
mechanism after 30 minutes. If i'm using a program that's on the volume in the
Bernoulli, and it's powered down, it locks up my system waiting for the
Bernoulli.
I power down the unit, eject and re-feed the cart. all to no avail. Any
solution
anyone knows about?
LON
Larry,
I also have a Bernoulli 150. The spinning down of the hard disk is a
'feature' that, as far as I know, can't be disabled. There is a solution
– the is a program in library 13 of this forum called WAKEUP.LZH. It
simply runs in the background and writes and empty file to the Bernoulli
every 20 minutes to keep the drive spinning. You may give it a try.
Otherwise, you may try contacting IOMEGA here on CI$ to see if there is
any way of disabling this feature.
Rick – On Autopilot from Vancouver