CompuServe Thread

#ST296 / A2090 trouble

6 messages in this thread
#56181From: Jim GotwaldJul 7, 1989 8:43 PM
Anyone…. Help! I just iinstalled a new ST296N in my 2000 using an A2090 controller (while I'm waiting for my HardFrame2000). After a week, the ST296N stopped working. My old MiniScribe 8225 still accesses fine (when the Seagate isn't connected to the controller). When BindDrivers executes, the Seagate activity led flashes 5 times and the constantly flickers at a high rate. My question is this: Is it possible the 2090 could have developed a problem in the SCSI circuitry that would not effect the ST506 stuff, or should I be preparing to ship the Seagate back? Jim
#56215From: Don Curtis/SYSOPJul 8, 1989 2:08 AM
Jim, Get ready to ship it back….5 flashes means: Data Buffer RAM test failed. This is a problem with the Seagate, not the A2090. Don
#56323From: Jim GotwaldJul 8, 1989 8:15 PM
Thanks, Don. I'll get ready!
#56377From: Clifford ColesJul 9, 1989 7:27 AM
Pardon me- I have a question, assuming this discussion is about the HD light blinking upon being powered up. What does it mean if the light blinks eight times? I already replaced my HD, but I'm curious as to what was wrong with it. -Cliff
#56481From: Don Curtis/SYSOPJul 9, 1989 9:00 PM
Cliff, I'd love to tell you…but I cleaned up my room last night, and inadvertently threw away the sheet with the information on what the error codes were for Seagate drives. My memory is that 8 had something to do with maintaining speed within a certain percentage. This only delt with Seagates…other drives have other codes. I do have the codes for MiniScribes 8425's if anyone is interested. Don
#56496From: John DraperJul 9, 1989 9:56 PM
Cliff, Eight flashes means that the drive was unable to load its operating system from the drive. Here's the whole list… Flashes Meaning ——- ——1 Failed internal memory test 2 Failed ROM checksum test 3 Failed controller chip test 4 Failed program RAM test 5 Failed data buffer RAM test 6 Drive unable to attain or maintain spindle speed 7 Unable to find/read SECTOR ID MARK 8 Unable to read O/S code from drive 9 Bad O/S code read from drive This information courtesy Thad Floryan. -larry