CompuServe Thread

GVP SCSI problem

9 messages in this thread
#63010From: Steve jonesJul 17, 1992 2:53 PM
Has anyone had any troubles with the GVP combo board and its scsi interface? It seems the positioning of the SCSI cable with respect to the power supply in my A2000 is critical. If the cable is in the wrong position the amiga won't boot and comes up with GURU errors. If the cable is shifted while the Amiga is running, it comes up with hard drive errors. My hard-drive is mounted in the left hand drive bay. I was wondering if anybody had experienced this problem and whether mounting the hard drive on the back of the combo board might help. I've resorted to using my microbotics hardframe controller for the time being. It works without any problems.
#63059From: SyndesisJul 17, 1992 10:55 PM
I have a GVP combo board (33 mhz 030, SCSI, RAM) and a hard drive in both the left-hand drive bay and the 5 1/4 bay with no troubles like you mention. Maybe something is rubbing against something it shouldn't? I know the power cable does sometimes get caught near the RAM chips on the GVP board…
#63131From: Steve jonesJul 18, 1992 2:13 PM
My guess is my power supply is noisy and the scsi cable is picking it up. I might try switching the power supply and seeing whether that cures the problem. I think the location of the scsi connector beside the power supply might not be such a good idea. The hardframe 2000 controller which sits a fair distance away from the power supply might not be hearing the noise. Steve
#63344From: Gary NushJul 21, 1992 1:08 PM
Steve, It's also possible to have a broken cable (either near the header on the accelerator or on the drive) and moving the cable repeatedly breaks and makes the connection. It could also be a break in the middle of the cable, but the connectors are usually placed under more stress than just the raw cable… It's a thought… -=*) Gary Nush (*=-
#63448From: Steve jonesJul 22, 1992 1:03 PM
Thanks, I never thought of that. The cable I have now has some scrapes and it is possible that a connection is being broken. I'll try a new cable and see if the problem continues. Steve
#63383From: Pete GouldJul 21, 1992 5:52 PM
Steve, I had the same problem. In my case the SCSI cable is nearly 3 feet long as I use a Bomac tower with several drives. My solution was to build a SCSI cable using shielded ribbon cable. It's expensive stuff (about $10/foot) but it completely solved all problems. Pete
#63391From: Michael GerardJul 21, 1992 6:46 PM
Redmond cable will configure a shielded round scsi cable (36") for around $30. Michael …..on AutoPilot
#63477From: Pete GouldJul 22, 1992 6:38 PM
Michael, I shouldda known. Redmond can make just about anything! Pete
#63449From: Steve jonesJul 22, 1992 1:04 PM
I think I'll try a new cable first. If that doesn't work then I'll try the shielded scsi cable. Steve