CompuServe Thread

#Printer Cable

4 messages in this thread
#118113From: Barry NewmanAug 28, 1990 9:29 AM
CAn anyone give me the Epson pinouts for A-1000 DB-25 -> CEntronics please?
#118181From: Don Curtis/SYSOPAug 29, 1990 12:06 AM
Barry, Amiga A1000 pin Centronics pin 1 (strobe) 1 2 (data 0) 2 3 (data 1) 3 4 (data 2) 4 5 (data 3) 5 6 (data 4) 6 7 (data 5) 7 8 (data 6) 8 9 (data 7) 9 10 (ACK) 10 11 (BUSY) 11 12 (POUT) 12 13 (SELECT) 13 14-22 (GROUND) 19-30 23 (+5v) NO CONNECTION 24 NO CONNECTION 25 RESET 31 Normally, pins 14-22 on the Amiga side are soldered together and a single wire is run to pin2 19-30 on the Centronics side…which are also soldered together for ground returns. Don
#118541From: Barry NewmanSep 1, 1990 8:07 AM
Thank you Don, your first mesage kinda straigntened me out but I will go back and get GND on 19-30. I must assume your message had a typo in it when you said "…single wire is run to pin2 19-30…" as pin 2 = Data0. IF this is not the case, please let me know Thanks again for all your help – you're a great Amiga Resource!
#118675From: Don Curtis/SYSOPSep 2, 1990 2:03 AM
Barry, Yes…that was a mistype…it was supposed to be "pins 19-30" Don