#128206From: RON TROYJan 15, 1994 9:58 PM
After installing a Super Denise on my 2meg chip ram equipped 2000, I get a requestor for trying to reset the workbench screen. Can anyone tell me what this is and how to deal with it? At this point, the system does appear to be running normally otherwise. I did have a lot of trouble at first, though. I have not normally kept any monitors listed in the devs:monitors directory, but now I have ntsc and pal. I run a 1084s. I am using ados 2.1. Thanks, Ron
#128227From: Karl F. KugelJan 15, 1994 11:51 PM
You have something in the Startup-sequence prior to IPREFS that outputs to the screen. Find it and redirect the output to NIL: (i.e. "XXXXXX >NIL:"). That will solve your problem. // -Karl \X/ Amiga and Autopilot: The *only* way to fly!
#128335From: RON TROYJan 16, 1994 8:46 PM
It seems to be gone now. Apparently when I was messing around with s-s to get my system working after the denise upgrade I put in some echo's. The actual problem was that I didn't have any 'monitor files' like NTSC and the startup didn't like that one bit. It didn't matter with the old denise. Once I put them in and restored my original startup I was fine. Any suggestions on how to use the new modes of the super denise? Thanks much, Ron
#128362From: Karl F. KugelJan 16, 1994 11:59 PM
Not really. I'm using a Flicker-Fixer, and they weren't compatible with the ECS modes. So I'm stuck with high res interlaced. Of course, since almost all programs support that mode, I would be using it most of the time anyway. I have *seen* the ECS modes on other machines, though, and I expect you will have to play with the fonts to get much use out of it. // -Karl \X/ Amiga and Autopilot: The *only* way to fly!
#128450From: RON TROYJan 17, 1994 5:42 PM
Understood. I suspect that I'll also have to find not just a different font size but a different font. And its desire to reset everything each time you make an adjustment seems to need a reboot to really work, so these changes are a pain in the but. Thanks, Ron
#128232From: Brian BartlettJan 16, 1994 12:19 AM
Ron, if you are seeing the requester that asks to reset the Workbench screen, then you have a program in your startup-sequence, prior to the call to IPrefs, that is getting a lock on the screen. Doublecheck your startup sequence to make sure that all programs prior to IPrefs have their output sent to NIL: as well as input. Brian bjbart@watserv.ucr.edu
#128336From: RON TROYJan 16, 1994 8:46 PM
All cleaned up now. Thanks! Ron
#128395From: Brian BartlettJan 17, 1994 4:31 AM
Ron, your welcome. That problem drove me to distraction when it happened to me. Brian bjbart@watserv.ucr.edu