#67007From: Mike HobartOct 26, 1993 3:18 AM
I've got a GVP Combo/040 board in my A2000 and I recently had to replace a failed Quantum LP105S drive. I installed a Maxtor 7345S drive as a replacment and I'm running into some problems. 1) It seems like the drive needs to warm up before it operates properly – when I first turn the system on I often get a number of read errors on blocks which disappear after the system has been on for a few minutes. 2) Related to that, what does the message "Unexpected Result $49/$46" mean from the GVP SCSI controller? I know that the drive problems aren't your business, but have you had reports of other problems with this combo? Is there a problem with this combination, or just this drive. I also have a Toshiba XM3201 CD-ROM drive and a Syquest SQ555 drive on the SCSI bus. Thanks in advance, Mike Hobart
#67603From: GVP TechNov 4, 1993 8:47 AM
Mike, You may have to change the "power-up option" jumper on the Maxtor. I do not have specifications on that drive, so I cannot tell you precisely which jumper that is. In regard to the error message ("Unexpected …"), the AmigaDOS requester that appears will display a UNIT NUMBER or a BOARD NUMBER. This tells us what specific drive (or board — most often the drive) is having a problem. Next time that error appears, look at the UNIT NUMBER and find the corresponding SCSI device. You may have to change a setting in FAAASTPREP (such as Disconnect, etc.). Pete GVP Technical Services
#68306From: Mike HobartNov 14, 1993 3:21 AM
Thanks for the reply. The message was coming from SCSI device 0, which was the Maxtor drive. After reconfiguring the drive chain, I'm not encountering the problem. I WAS wondering what the $49/$46 message meant.