CompuServe Thread

#'Budgie' chip

12 messages in this thread
#215311From: Jim SteeleOct 14, 1995 11:34 AM
The clocks are generated by the 'Budgie' chip, from a main oscillator. That osc is 28.63696 mHz for NTSC and 28.37516 for PAL. The NTSC color burst is generated from it, so I'd say that you'd have to have the right crystal to generate NTSC *composite* video. The power supply only supplies DC, so there's no way the system could decide pal vs/ ntsc that way. It must be internal… Now that I look at the prints again, I do see the jumper. it's R203, which grounds a signal called \ntsc. Looks like you'd have to move R245 to R246 as well. Then you'd have to change the RF modulator- it's a sealed can. If you only wanted composite video, you could get away with the 3 jumpers & changing the main osc. At least, that's what I think after looking over the schematics. It's been a while since I opened up a 1200. -Jim MOS via Autopilot & Amiga
#215470From: Phillip WoollerOct 16, 1995 5:23 AM
From what I read I though that you could get a clock from the power supply, I suppose if it is dc then you can't. I will check the docs again……. Phill
#215523From: Jim SteeleOct 16, 1995 7:27 PM
The 2000's power supply supplies a line frequency 'tick' signal…. but the 500 and 1200's do not. . -Jim MOS via Autopilot & Amiga
#215578From: Phillip WoollerOct 17, 1995 5:26 AM
Ah, that must be it, I assumed that all power supplies had this, I wonder why the 2000 has it but no others…. Phill
#215647From: Jim SteeleOct 17, 1995 7:41 PM
That I don't know. I do know it's a jumper option in the 2000, whether to use the power supply tick line or vsync (what the 500 uses). But I never heard a good explantion as to why you'd want one over the other. -Jim MOS via Autopilot & Amiga
#215691From: Phillip WoollerOct 18, 1995 11:39 AM
What are 2000's jumpered for normally the power line or vsync? Phill
#215828From: Jim SteeleOct 19, 1995 5:53 PM
They're set for power line. There was a CBM tech bulletin warning that some 2000's were set wrong at the factory. They said that this would cause problems with 3rd party genlocks… but that's all they said. -Jim MOS via Autopilot & Amiga
#215909From: Phillip WoollerOct 20, 1995 10:23 AM
Strange that they work off the power line, that must be one of the least exact timing methods you can get, maybe that's why cbm chose it 🙂 Phill
#216030From: Jim SteeleOct 21, 1995 12:57 AM
Actually, I think the power companies hold the power line frequency pretty closely. That's what lets them buy power from each other… And a drifting power supply frequency would cause havoc with clocks and other syncronous motors. Back when I was a field engineer with Burroughs, a drunk took out the power & backup to a customer's data center. They tried to power the place with a trucked in diesel generator. Unfortunately, the thing couldn't hold a frequency under changing loads. All the disk drives in the place went nuts, cuz their motors were changing speds. -Jim MOS via Autopilot & Amiga
#216263From: Phillip WoollerOct 23, 1995 4:30 AM
In the uk the power line frequency shifts quite a lot, it averages out over the day though, which is why clocks manage to keep time. The uk power supply is also never exactly 240 volts, we checked a volt meter at work the other day and got 245 volts. It wouldn't suprise me if at some times of the day it drops to 235 as well. Phill
#216313From: Dan NamayOct 23, 1995 3:47 PM
> In the uk the power line frequency shifts quite a lot, it averages out over the day though, which is why clocks manage to keep time. The uk power supply is also never exactly 240 volts, we checked a volt meter at work the other day and got 245 volts. It wouldn't suprise me if at some times of the day it drops to 235 as well. Phill, Motors and other electrical equipment are usually rated to run on plus/minus 10% of their VOLTAGES. The frequencies remain constant. In the US it's 60hz and in Europe (I believe) it's 50hz. The voltages can fluctuate, but the frequencies should stay relatively constant. Wolf Pup — Howlin' in the Waves…
#216356From: John DraperOct 23, 1995 8:02 PM
Phillip, <The uk power supply is also never exactly 240 volts, we checked a volt meter at work the other day and got 245 volts. It wouldn't suprise me if at some times of the day it drops to 235 as well.> Same thing is true on this side of the pond (at least here, in northern California), though the numbers are different…:) That's one of the reasons I got a line conditioner for my A1000 many years ago, and have my A2000/040 hooked up to a UPS. Not only does it protect me from surges and spikes and uneven electrical current, but it also gives me up to 20 minutes after the power is out completely, to gracefully close down my system. Asha @}–,–`–