CompuServe Thread

#PAR problem

5 messages in this thread
#135906From: Christophe Van OyenNov 14, 1994 3:58 PM
Today I reformatted my PAR drive, after the problem I had last week when I deleted a project directory and things messed up. After reformatting I created a few new prj directories and copiedmy backed up files again onto the PAR. Then the following happened, all stills which are mainly the colourbars where copied back on without any problem. But when copying back one animation, when playing it on the PAR (1250 frames) At about 3/4 the images went shaking like when you get when your Block Limit is set to high so I overdid the whole process and the same happened at the same place. However that animation played OK on the PAR before I formatted the drive, did something go wrong when exporting the ANI to a DOS disk??? How can I put this right, I luckely still have the TGAs to recomposite the animation in about 2.5 hours through videopost, but what happened this eems still to be some kind of bug??? BTW does anyone know when a future software upgrade solving some of our encountered problems mey be out or available, btw where are the DPS people on this forum they seem to have vanished in the last 3 weeks??? Christophe
#135931From: theo van bruggenNov 14, 1994 4:58 PM
Christophe, The problems are know to the DPS-people ( I think Brick is on a fair somewhere in the UK). Will be back this week or so. We are getting more and more to the basics of the problem. I will keep you informed. I hope this message will reache you because i'm working on my Notebook now and didn't install the WINCIM.
#135964From: ROBERT RITGERNov 14, 1994 6:56 PM
I have had a similar experience but I didn't share it as I thought it had more to do with Pathworks and OpenVMS than anything PAR related. Anyway, can you confirm that your .ani files when copied back to the PAR drive all play for the same duration (for me 0-127 frames were good, frame #128 was the first of the frazzled frames)? I had five different segments and all went bad on the exact same frame. I had copied my files from the PAR to a DEC Alpha via Pathworks' NFT 'copy' command. Reading up I found that I needed to put in the /block qualifier to allow longer records to be transfered. Were you copying your files back and forth with DOS commands? There may be some qualifier which you may need to use as I required. Gus would be the guy to talk to I suspect.
#136274From: John RedfernNov 15, 1994 5:32 PM
This is just a thought 'cos I haven't tried it yet, but if you record an ani on the outer tracks that allow a high block limit, then back-up to dos disk and then later restore to a fuller PAR drive; you may be putting it back where a lower limit is required. What then?
#136186From: Sean HowardNov 15, 1994 12:05 PM
I know that the PAR has a problem with overheating. I currently have an Amiga version that I had to drill out the back of the case and install a fan. Since then I have had no more problems with it "freaking out" every once in a while (except when I delete projects! <BG>) Hope this helps… (You can try just removing your case cover from your PC and if the problem goes away, it was heat/ventilation related…) Sean // Dreaming of being helpful for a change //