#14507From: Christopher LapriseFeb 7, 1991 1:40 PM
Here is where I would really welcome some input.. I have been through 4 CIA chips in the past 6 months. I consider myself to be generally cautious with my equipment, but I must be doing something wrong here. My parallel port is connected to an A/B switchbox (metal case, plastic rotary switch/knob). I think that I may have been causing damage by using the switch, esp. while the peripherals I'm switching between are ON. I was most often switching between A) a PAR-NET cable and B) my printer. Sometimes I would use Digi-View or Perfect Sound in B) instead (only plugging/unplugging from 'B' when the unit was switched to 'A'). Current Status: System freezes when printer runs out of paper (paper-out signal), computer keeps incorrect time (the volatile system clock), and Digi_view, P.Sound and PAR-NET are un-usable. Now, I only turn the switch when all peripherals are OFF to try to prevent further damage. However, I do not want to invest in replacement chips until I am sure of the culprit.
#14523From: Bob RakoskyFeb 7, 1991 6:01 PM
Christopher, Your problem is obviously related to attempting to expand your A500 beyond that for which it was designed! (<grin>) On a less sarcastic, more serious note: I have been told that many switch boxes are designed with a parallel printer in mind, in which case they are only expecting one-way communications, and are designed accordingly. I seem to remember such a warning either in the Perfect Sound manual or in one of the "read.me" files included with the Perfect Sound package. Since the devices to which you are switching are talking 2-ways on the Parallel Port, this may be part of the problem. I know that I have decided to do the power-down/reconnect peripherals when switching to/from my Perfect Sound, rather than attempt to use one of the many switch-boxes I have sitting around here because of this warning. Good luck in tracking this down, and hope this helps…. …BobR
#14574From: Christopher LapriseFeb 8, 1991 8:09 AM
Thanks Bob (for the serious stuff, anyway 🙂 I opened the box and looked around. All there is to it is this Frankenstein-looking rotary switch, having dozens of wires coming out it's side and to the DB connectors. It looks very well-made. As for two-way data, there seem to be no electronic components such as diodes, transistors, capacitors, etc. that would hinder two-way communication. Here's the scoop on the pass-thru: All pins passed thru EXCEPT 17-25, which are all soldered together and use a single wire. According to the parallel port schematic, this should do just fine (I have NEVER used this for Serial). I remember when I first got the switchbox that I did a continuity test on all pins, for both 'A' and 'B'. All the connections seemed good and (except 17-25) were completely isolated (no shorts or crossovers).
#14629From: Don Curtis/SYSOPFeb 8, 1991 11:16 PM
Make sure it's a 'break before make' type switch (which is probably what it is). Versus a 'make before break' switch. The difference between them is that break before make type switch disconnects from the 'A' side before it connects with the 'B' side (or vice versa) whereas a make before break connects the 'B' side before it disconnects from the 'A' side. in other words…all 3 connectors are momentairly connected. One other thing…those grounds (17-25) are probably connected all the time between all three connectors…that's ok.
#14983From: Christopher LapriseFeb 12, 1991 11:10 PM
I wish I could look inside the barrel of the switch to see if it breaks contact with 'A' before engaging 'B'; However, the barrel is rather well-made plastic and steel, but doesn't look like the 'servicable' type of component.
#14998From: Don Curtis/SYSOPFeb 13, 1991 2:04 AM
Easy way to test…simply put a continuity tester between a pin on the A input and the same numbered pin on the B input (but not one of the grounds though) and slowly flip the switch. If the tester jumps..or indicates continuity at any time…you've got a make before break type switch.
#15031From: Christopher LapriseFeb 13, 1991 9:47 PM
I tested the switchbox like you described with my Ohm meter set to audible continuity-check. I tried several times, turning the switch as slowly as I could back and forth.. Not a peep or a flicker in the display. So I guess the switch is not the culprit. Thanks for your suggestion; It eliminated a major unknown.
#14530From: Black Belt SystemsFeb 7, 1991 7:08 PM
Question: Does/did your printer have a 3 prong cord, which has been changed to a 2 prong; or, is it a three prong into a two prong (like into an extension cord), such that the prongs could be turned around in the wall? This can (and often has) blow out your CIA chips. Static… you need to be *sure* that you touch the case of the amiga with the printer cable shell *before* you plug it in. This dicharges and delta-EMF between the printer and the computer that was generated as a static charge (no matter how it got there). Use the shell – NOT the area of the cables with the pins. Hope this helps. Ben Amateur Radio Callsign is A A 7 A S
#14575From: Christopher LapriseFeb 8, 1991 8:09 AM
Ben, As a matter of fact, I had the printer on a three/two-prong adapter for quite a while; Not for lack of a grounded outlet, but because NewTek (and others) recommend that only the computer should be grounded (the peripherals using the computer's ground) to avoid a "ground loop" phenomenon. I remember always pluging the printer in with the correct polarity, but that is memory and I suppose just one time backwards is enough to cause all this. More about the PAR-NET cable.. It's 35' ribbon cable, unshielded, running along the rug from the living room (which has the 'server') to the bedroom (with the little 'client' setup). This runs from the client's parallel port to the 'A' connector on the server's A/B switchbox. There is also the 3' full pass-thru ribbon (unshielded) cable connecting the server's parallel port to the switchbox. Everything seems to work with the switchbox – Digi-View, P.Sound, the printer and the net cable… For a while that is.
#14603From: Black Belt SystemsFeb 8, 1991 7:00 PM
Ah… not to use too strong words here, but, whoever told you that "only the computer should be grounded" is (1) out of their tree; (2) advising you to do things that, if a fire were to start, are solid grounds for a winnable, reasonable lawsuit; (3) have such little connection with reality one has to wonder if the individual you spoke to has looked at anything to do with grounds since the last time they burned their coffee. Connect *all* your grounds. It's very likely that you will cease to lose CIA's and so on. Ben Amateur Radio Callsign is A A 7 A S
#14607From: Steven WartofskyFeb 8, 1991 7:33 PM
Ben, Is there any, uh, convenient way to ground my mouse, then???……. 🙂 — steve
#14699From: Black Belt SystemsFeb 9, 1991 2:01 PM
It is grounded… the shell on the mouse connector at the AMiga end has (at least all of them that I have seen) a metal shell that is connected to the ground system. :^)
#14751From: Steven WartofskyFeb 9, 1991 10:53 PM
Interesting! This suddenly makes me realize that maybe some third-party mice and/or joysticks do _not_ have that metal shell, is this risky? Or is the ground across the pins adequate enough?
#14802From: Black Belt SystemsFeb 10, 1991 1:15 PM
I would say that without that metal shell, you may or may not have a good solid ground to the mouse. For RFI (FCC) reasons, a mouse cord is likely to require a shield; and that shield should be connected to the shell of the socket. That's usually what that metal shell on the cable connector is for – a solid RF ground. Static being pretty well unpredictable, my position is "the more ground, the better".
#14875From: Steven WartofskyFeb 11, 1991 8:25 AM
Hmmm, this is something to watch out for should one ever purchase third-party mice and stuff. I've noticed most joystick connectors don't have such a ground, is this something to start worrying about?
#14915From: Black Belt SystemsFeb 11, 1991 9:20 PM
From my point of view, which is admittedly sort of a right-wing hardware worst-case kind of view, yes. I look at the connectors before I buy anything.. I have an extra worry, though – I'm a HAM radio operator, and if "things" start emitting massive amounts of radio frequency energy, my radio listening begins to suffer serious Bad Stuff. I've also been victim of two dead Amiga's, so far, as a direct result of static. One was killed by a SuperBase Dongle (plugging it in blew the computer to hell and gone… static went right in the mouse port and zing…) The other was an a1000 I plugged a SCSI controller into after walking across the room. I saw the spark… it took a week of screwing around before the machine booted again (from floppy!) THis all tends to trend ones thinking towards the conservative side.
#14926From: Steven WartofskyFeb 11, 1991 10:00 PM
<painful laugh> thanks for the report on your experiences, I think I'll be very careful around my ports from now on (as if I'm not already!).
#14984From: Christopher LapriseFeb 12, 1991 11:10 PM
I quote from NewTek's DigiView 3.0 *User's Manual*… Q."I see…interference pattern in my digitized images. What causes this?" A."This case of this is usually a ground-loop. A ground-loop can occur when more than one of the components in your computer system are plugged into your house current with a grounded (three-prong) plug. The computer is the only component that should be grounded, all other components should be un-grounded by using a 3 to 2 prong adaptor on their power cords." Immediately following this paragraph, there is a section on diagnosing and servicing damaged CIA chips! If this really IS the cause of the damage, then can I hold NewTek responsible? This is getting rather expensive for me.
#15068From: Black Belt SystemsFeb 14, 1991 1:28 AM
You bet. Or if your house catches fire, or if you get a debilitating shock from a reversed two prong cord, or an unisolated or reversed hot-chassis monitor happens to kill your youngest child or your dog or your cat (nah, cats are too smart) or your elderly grandmother. AC current, as supplied in the wall of your home, is generally not polarized – IE, one lead isn't any much more dangerous than the other. Both (either) can KILL you. Some monitors (old ones, as far as I know) and televisions, use what is called a HOT chassis. THis is where they take one side of the AC line and connect it to the metalwork, which (here is the kicker) is also usually connected to the signal ground, like the cable wires and video inputs and so on. You notice that most AC plugs have one prong wider than the other last few years? THat's so you can't plug in the cord the wrong way. If you *do*, you have connected the opposite side of the AC line to the montior/equip/.etc. Now, in the three prong thingees, the ground (the third round pin) is sorta the same as the side that is supposed to be common (ie to ground in HOT chassis designs). You reverse the hot on your monitor, connect cable to something else (like your Amiga) and you essentially have connected one side of the AC line to the other, THRU your Amiga. BOOM! THings die – maybe YOU, if you happen to be holding the wrong thing. But probably your Amiga. You might be safe, those wider bladed plugs can help. Bottom line: One of the main reasons that we have those polarized plugs and plugs with grounds is to make things safe. You defeat it, and you are literally playing with fire. Don't do it. Ever. For any reason. Find another solution.
#15120From: Mike SchillerFeb 14, 1991 8:13 PM
And of course nobody ever mentions that the whole idea of 2 prong outlets was the big con pulled by the electric companies around the turn of the century to sell people on AC power rather than DC power! It seems like now that everyone's forgotten that fact that they're now saying "you should only plug things in one way" which is exactly what they told people you wouldn't have to do anymore with AC power.
#15157From: Don Curtis/SYSOPFeb 15, 1991 12:13 AM
That's absurd. There's a major reason why sockets are polarized now (and have been for perhaps 30 years or so)….your safety.
#15218From: Mike SchillerFeb 15, 1991 11:06 PM
That's exactly my point. Back in the days (around the turn of the century) when the power companies were supplying DC power, they switched over to AC because it's much cheaper for them (and really everyone) for several reasons. In order to convince people that they should switch over to AC power (and replace any appliances that wouldn't work with AC) they made a big deal that you wouln't need polarized outlets with AC (like you do with DC).
#15228From: Malcolm O'BrienFeb 15, 1991 11:32 PM
Oh, Mike! That's the least of the differences between AC and DC power. For my money, Tesla's system beats Edison's, no contest!
#15264From: Black Belt SystemsFeb 16, 1991 3:30 PM
First… you should NOT have to worry about which way things plug in. The reason that you DO, is because certain manufacturers took some rather stupid liberties with the AC system, I'm speaking specifically of the hot-chassis designs. Second, N. Tesla, who espoused AC power over DC power, did so because he felt (correctly) that AC power was a mcuh more efficient means of getting energy from here to there; compensation for transmission losses was easy and inexpensive (IE, transformers). DC power, as pushed on the public by T.A. Edison, was not economically practical for this reason alone, although there are others. If there ever was a "Big Con", it was perpratrated on the public by Thomas Edison, a man who has gone down in the history books as a positive figure… when he (a) ruined Tesla with lies, propaganda, and just plain idiot claims, and (b) foisted DC power off as a practical, mass-distribution power system, which it was not then and is still not now. Ben Amateur Radio Callsign is A A 7 A S
#15475From: Malcolm O'BrienFeb 19, 1991 1:23 PM
Ben, Completely agree (as usual <g>) about Tesla vs. Edison. But Edison was a better businessman. Malcolm
#15562From: Black Belt SystemsFeb 20, 1991 8:39 PM
UNfortunately, then, as now, being a b*stard is usually an asset in business. A lying, deceitful, self-centered b*stard, in T. Edisons case. Ben Amateur Radio Callsign is A A 7 A S
#15032From: Christopher LapriseFeb 13, 1991 9:47 PM
If you see me complaining to NewTek in AmigaVend, you'll know I could use your input.
#15069From: Black Belt SystemsFeb 14, 1991 1:29 AM
I'll give you input in here… you need opinion, ask. I'd rather not turn on the NewTek section in Vendor… I'm about at my limit of message reading/replying as it is.
#14632From: Don Curtis/SYSOPFeb 8, 1991 11:22 PM
Ah…and there is your problem more than likely. The 35 foot ribbon cable running on the rug. As I'm sure you're aware…significant static charges can build up on a rug especially in the winter when the air is drier. The insulation on a ribbon cable is not enough to stop that charge from getting in the wire. Do one of two things. The best would be to use a shielded round cable instead of a ribbon cable. That way…the static charge will go into the shield and to ground with no effect on the operation. The other would be to spray the rug where the ribbon cable is running with something like Static Guard once a month. Spray it until the rug is damp…but not wet of course. (Oh…#1 above presumes the shield is connected to ground)
#14985From: Christopher LapriseFeb 12, 1991 11:11 PM
Thanks.. I can try the static-guard aproach, but the connectors on each end of the cable are all-plastic (unshielded). I would have to rebuild the cable to implement shielding, and then I'd have to find another use for 35' of 14-wire ribbon cable.