#3D Studio r3 Page Faults
2 messages in this thread
Waiting for r4 upgarde and just now installing r3. Ran through every
step of installation twice now, and have same problem nomatter what.
Even cut back AUTOEXEC.BAT and CONFIG.SYS to the bone and had exact
same problem. And also upgraded DOS to 6.22. I install 3DS and when
I run 3DS VTABCFG (or even 3DS, or 3DSHELL) when it attempts to run I
get this:
Initializing Autodesk 3D Studio…
Abnormal program termination: Page fault
CS:EIP = 000Fh:00230FE3h
(also had CS:EIP = 000Fh:00231063h)
Any hints…? Or should I just wait for r4…???
Scott
Scott,
Page faults can be the result of a memory conflict, or something
interfering with your hardware capability to write to the hard disk.
Follow the procedure below for diagnosing a memory conflict. If that
does not work, then the problem is most likely in your hardware. I
would then run a full diagnostics on your RAM chips (one might be
bad), on your hard disk controller, and your hard disk.
-Brian
Title: Clean system boot; diagnostics for memory conflict…
Description:
To confirm that the problem is caused by a memory conflict, re-start the
computer with simplified settings (a 'stripped system') and see if the problem
goes away.
For DOS-only computers, a stripped system means that the computer is rebooted
without terminate and stay resident (TSR) programs nor device drivers that are
not absolutely necessary for the operation of the operating system and
computer. The Autodesk program should also be configured for VGA display if
possible, to rule out display driver conflicts.
To reboot into a stripped system for 3D Studio and Animator Pro, change the
system files as follows:
CONFIG.SYS should contain only:
FILES=40
BUFFERS=20
AUTOEXEC.BAT should contain only:
PATH=<your path>
PROMPT=<your prompt>
You may want to use the DOS SYS command to create a bootable floppy for this
trouble-shooting exercise and place these simplified system files on the
diskette. Or, you may edit the existing CONFIG.SYS and AUTOEXEC.BAT files
currently on the hard disk (make back-up copies first). Make sure you have a
bootable DOS floppy on hand, just in case the computer has trouble rebooting.
Note: Quarterdeck QEMM users may find it helpful to review the QEMM
trouble-shooting documentation and use the Analyze utility to track down memory
conflicts.
Trouble-shooting:
If the program now operates correctly, the next step is to determine
which program or driver in your system files is causing the conflict.
Edit the CONFIG.SYS and AUTOEXEC.BAT files, adding one device driver
or TSR command at a time, rebooting, and starting 3D Studio/AAPRO
until the error reappears. When the error happens, the last item you
added to the configuration is probably the trouble maker. Once we
know which drivers are conflicting, we can determine the proper
course of action.
If you are using special display adapters (for example, a Targa frame buffer),
you should check the documentation that came with the display driver to see if
special memory settings or EMS exclusions are needed.
-Brian