CompuServe Messages

#SCSI Problem.

    30-Jan-94 01:16:23
Sb: #73307-#SCSI Problem.
Fm: Trent Hawkins 73614,533
To: BILL LEACH 71330,2621
Bill, Thanks. I also received a post from Gary Nush that explains the Wangtek/SCSI problem quite well: –>"The Wangtek tape drive compatibility problems are due to a 'disagreement' between the way the Wangtek tape drive handles disconnect/reconnect and the way the WD SCSI controller chip handles it. GVPSCSI.DEVICE tries to handle it can, but turning it off is the best way to avoid problems. The Unexpected Status errors are generated by he WD chip itself and passed on to GVSCSI.DEVICE for reporting. The numbers are sort of like GURU meditation numbers, where the second number's definition is different based on what the first number is. The list of all of them can be found in any WD devices book. By the way, WD stands for Western Digital. Gary Nush Product Manager, Amiga Division Great Valley Products, Inc." So I suspect it is, like Gary says, a problem between the Wantek drive and the WD chip. No problem, as GVP has been kind enough to pass along a program which corrects this problem. –>"you should have connect/disconnect OFF for the Wantek and ON for all HDs that support the feature" Well, I am running with the disconnect OFF for all my SCSI devices (and they all work, including the HD's). The only difference between the Wangtek and CD-ROM to the two hard drives is that the hard drives disconnect ON/OFF button can be initiated from EXPERTPREP on the FAAASTPREP disk (page two of EXPERTPREP), while neither the Wangtek nor the CD-ROM can have the disconnect turned off/on from this page. Trent Flying near the Pole in the Great White North