#85750From: IAIN WHITEHEAD.Jul 4, 1994 1:44 PM
ANYONE, I have recently bought a copy of GVP's ImageFX 1.5 and it doesn't work – or at least the scanner section doesn't work. I installed the program as advised onto my hard drive and everything went well, it loaded OK. I followed the instructions as per Chapter 2 and 3 of the manual. With regard to the scanner I selected the EPSON option (though I notice the manual says it only supports the EPSON 300C) the guy in the shop (SILICA, Glasgow) told me it would work with my EPSON GT-8000. From page 5-3 of the manual I attempted to run the scanner module, but all that happened was that the ready light on the scanner went out and the 'watch/busy' icon on the screen appeared …… and that was that – nothing else happened. According to the manual I should have been put into the scanner option frames but this does not happen – all I am looking at is the 'watch/busy' icon. It does not look as though the computer is freezing up as I can move the icon easy enough but if I press elsewhere on the screen nothing else happens. Can anyone advise? My system is:- AMIGA1200 M1230XA 50mhz accelerator with 68882 50mhz co-pro 8Mb fast ram 250Mb Maxtor IDE hard drive. EPSON GT-8000 flat-bed scanner. also connected to computer is SupraFax v32bis modem and 1960 monitor. Thanks for any help anyone can offer. IAIN. CALLING IN FROM SCOTLAND ON A 68030/50/50 AMIGA1200! ON AUTOPILOT 1.72
#85815From: Kermit WoodallJul 5, 1994 9:42 AM
Iain, you do not mention what sort of cable you are using with your Epson scanner. We support two types of cables; the ASDG style and a faster cable designed by GVP. Regular printer cables do not work. What you will need to do to connect your scanner is connect using one of these cables, select EPSON as your scanner module, then select SCANNER from ImageFX. Wait (up to a minute) for the scanner menu to appear – WITH THE SCANNER TURNED OFF. The long delay is for broad compatibility with various scanner models and models of Amigas. Once the menu appears, select the Options… item on the menu. Change the cable type to whichever you are using. Go to PREFS and save your settings. Power EVERYTHING off then turn the Amiga and the Scanner on. Everything should work now. Kermit Woodall Nova Design, Inc.
#85838From: GVP TechJul 5, 1994 3:35 PM
Iain, The EPSON scanner requires a special parallel port cable for proper operation. ASDG sells such a cable with their software upgrade for EPSON support. Redmond Cable in the U.S. also sells a GVP EPSON cable for use with ImageFX. Both of these cables will work, with a selection in the EXTRAS menu of the EPSON module. If you have the ASDG cable, you'll need to remove the cable, turn on your machine, change the selection in the EXTRAS menus to show ASDG, and then save your preferences. YOu can then replace the cable and use the scanner. GVP TECH