CompuServe Thread

#TERM Help Needed

28 messages in this thread
#120173From: Rob StantonOct 30, 1993 11:59 AM
I need some help setting up TERM (v3.4) to work correctly. I ahve never used TERM previously, but have heard it is an excellent program. However, I cannot seem to get to work correctly. One of the problems is that when it first logs on the text from the Host appears to be in a foreign language. Also, in the DOCs there is a mention that you can send some commands, specifically '/p' for the password, but I cannot determine the context which you can use these commands. I need TERM for the Kermit protocol on InterNet. By the Way, whatever happened to JR Radigan & JR-COMM. I like JR-COMM, but no Kermit protocol and no ability to edit translation tables. Thanks for any info. -Rob-
#120176From: Adrian NealOct 30, 1993 1:22 PM
Rob, Having just completed a quick sesson with Term 3.1 with the settings below I know they work with that version and I would think they work with 3.4 as well. Anyway give a go. Serial preferences were as recommended by CompuServe ie 9600 baud, "7-1-E". Within Term use the "Settings" menu and "Serial" option, it should be near the top. Baud Rate : 9600 Strip bit 8: (tick) Bits/char : eight High Speed mode: (tick) note I think this is the actual trick Parity : none check carrier: (cross) Stop bits : one shared access: (cross) Handshaking: RTS/CTS(DSR) xON/xOFF: (cross) Duplex : full I hope that they work for you. Good luck Adrian
#120355From: Rob StantonOct 31, 1993 5:18 PM
thanks, But what does tick and cross mean? I will play around with these settings and see what happens. -Rob-
#120463From: Adrian NealNov 1, 1993 8:07 PM
A tick means to select the item, a cross means not to select it. Sorry I didn't make myself clearer. Adrian
#120558From: Rob StantonNov 2, 1993 10:19 PM
Thanks, I kind of figured it that was it , but wanted to be sure. Also, another tip from a user here on CIS led me to try using 8-N-1 and to select (er tick) the 'strip last bit' and that also worked. I am also looking forward to checking out Terminus since I have used JR-COMM for awhile. Maybe some day I will even get around to checking out AutoPilot. Thanks for all the info, -Rob-
#120642From: Adrian NealNov 3, 1993 9:36 PM
I would try AutoPilot, I did and registered it almost straight away. I stii\ll log on manually once and a while, but most of my work on CompuServe is "done on AutoPilot". Adrian
#120980From: Rob StantonNov 6, 1993 8:05 PM
Adrian, I notice a lot of people use it, and swear by it. Guess I am getting set in my ways. -Rob-
#121203From: Karl F. KugelNov 9, 1993 1:14 AM
If you are still reading and writing replies in the forums on-line in real time, you will kick yourself for months once you try Autopilot. It's not just the savings- although they are large- it's the tremendous increase in convenience. History for any message is only a button click away- did you ever wonder what a reply replied to? The complete catalogs for all the files in a forum are right there- browse and select the files you want off line, and they get automatically downloaded when you next go on-line. And best of all, you get to compose your messages off line in a decent editor, split screen with the message to which you are responding. And the demo version of Autopilot is free for the downloading.
#121391From: Rob StantonNov 10, 1993 7:55 PM
I have to admit, I have many times wondered what a reply, replied to. BUT, what about documentation? The major problem with most shareware/PD is lack of comprehensive documentation. That is the problem with TERM. JR-COMM, er Terminus, on the other hand has a 200+ manual. How extensive is AP's documentation, and can you just order the non-demo version without first downloading the demo version to get the registration info? -Rob-
#121444From: Karl F. KugelNov 11, 1993 1:58 AM
The docs are pretty good, although they are a couple of revisions behind. But the changes doc does a good job of covering the new features, and Autopilot has its own section in AmigaVendor for support. Ap doesn't NEED the kind of docs that Terminus does, since it is meant for use only on CIS and thus doesn't need as much flexibility. Its major limitation is that it is limited to reading forum messages and downloading files (it can display online GIFs like the weather maps too) so if you are doing a lot of other things on CIS it may not be much help. It does have a "hands on" mode for manual use, so it is perfectly usable for those other things, it just isn't an improvement. The demo is the easiest and best way to get AP- First, you determine if AP is what you want, Second you get it set up properly, and when it is working, you register it here online (and get charged for the program). The authors send you a magic email which automatically enables all features of the program. You do need 1) a hard disk with no less than 5 megs free – the history files and catalogs are BIG, 2) 2.04 or better, 3) one Meg of chip Ram or better and at least 2 Megs total, and 4) a deinterlacer of some sort is strongly recommended. Note that the docs are in a separate file. The files you need, all in library 9 (Autopilot) of Amigavendor, are: Ap.lha, apdocs.lha, and change.lha. Updates, at least so far, have been free. // -Karl \X/ Amiga and Autopilot: The *only* way to fly!
#121660From: Rob StantonNov 13, 1993 7:59 PM
thanks, I am going to give ap a try. -Rob-
#121274From: Adrian NealNov 9, 1993 8:45 PM
There's nothing wrong in continuing to use something that is familiar. I do like AutoPilot as I think it saves me a small fortune :-), however there are times that AutoPilot is just not man enough for the job. Then I log in manually. You could argue that by always logging manually you are more familiar with the CompuServe enviroment.
#121394From: Rob StantonNov 10, 1993 8:02 PM
As you can tell by my ID#, I have been around CIS for awhile. I may give AP a try. I don't mind change, it is just that a lot of shareware has poor documentation, and it is really frustrating to figure out how to use a poorly documented program. Although I will say, I cannot recall any program with such excellent testamonials. I will give it a try and see how I like it. -Rob-
#120362From: Rob StantonOct 31, 1993 6:21 PM
Adrian, Changing to 7-E-1 works! Thanks.
#120377From: Christopher TolmieOct 31, 1993 10:49 PM
Rob, Changing to 7-E-1 works to get rid of the logon garbage text but I don't think your gonna succeed with downloads. It requires 8-N-1 and you can't switch settings in mid-session. Christopher
#120554From: Rob StantonNov 2, 1993 10:00 PM
Thanks, I also 'checked' the 'strip last bit' and it also worked as far as getting rid of the garbage. If I use this setting, I should be able to download OK? -Rob-
#120180From: Tim LloydOct 30, 1993 1:48 PM
protocol on InterNet. By the Way, whatever happened to JR Radigan & JR-COMM. I like JR-COMM, but no Kermit protocol and no ability to edit translation tables. Thanks for any info. -Rob- Boy are you out of date ! :^) JR-COMM has been totally re written by Jack, and is now called Terminus, latest version is 2.0C, and I think it's available in the file area… Check it out. Tim On AutoPilot Over Hong Kong
#120356From: Rob StantonOct 31, 1993 5:21 PM
Thanks for the info. I can't beleive I missed that. I am a registered user of JR-COMM and would have thought I would have been notified. Has he opened up his BBS again as well? -Rob-
#120428From: Tim LloydNov 1, 1993 12:10 PM
As far as I know yes his BBS is still going…. I have seen it mentioned several times on the Amiga International Echo. Tim On AutoPilot Over Hong Kong
#120433From: jack radiganNov 1, 1993 2:14 PM
Rob, The BBS was never closed, just relocated. I've always been available here, on GEnie, BIX and via USENET/INTERNET as well. As for notification. I've thought about doing a mailing, but with all the different comm programs available today and the low upgrade cost from JR-Comm to Terminus, I'm not sure that it would be cost effective. -jack-
#120557From: Rob StantonNov 2, 1993 10:12 PM
Hi Jack, Long time no "see". I thought sure you closed your BBS except to beta testers. Well anyway, my upgrade request was mailed yesterday to Ocean City, NJ with a note. Two things, OK 3 things, 1. What is the new BBS # 2. Is the name database the same or do I need to register as new 3. I spent a half-hour downloading terminus from compuserve (someday I will upgrade from a 2400 bd – maybe) and it would not start. I kept getting a system error "unable open library". Could not figure out what was going wrong. Might want to make sure that even people like me can get Terminus up and running. _Rob- P.S. Delighted to find out you are still enhancing your telecommuniications program.
#120724From: jack radiganNov 4, 1993 7:22 PM
Rob, The BBS # is 609-398-7453. If you had an account on there it should still be there, I rarely delete accounts. The library message is probably related to the file requester library. It needs version 38 (AmigaDOS 2.1) of asl.library or reqtools.library. Otherwise, it needs req.library for AmigaDOS 1.3. -jack-
#120981From: Rob StantonNov 6, 1993 8:09 PM
I am using 2.0. Doses this mean I am an "OS orphan", and if so, what do I do about it (without upgrading to 2.1 of course)? -Rob- P.S. And I understand that there is now an OS 3.1 for all computers
#121063From: Jim Shaffer Jr.Nov 7, 1993 8:21 PM
What's this about 3.1 being out for all computers?
#120233From: Christopher TolmieOct 30, 1993 9:29 PM
Rob, Set 8-N-1 and strip bit 8. In term select Settings Menu | Serial and checkmark select [Strip bit 8]. Use the settings 8-N-1 for CIS. You need to download at 8-N-1 and can't switch back and forth between it and 7-E-1 during a session. You can also ignore the garbage and continue the login sequence to get to the password, from then on the text will be clear. Christopher
#120357From: Rob StantonOct 31, 1993 5:22 PM
Thanks, I will give it a try. -Rob-
#120315From: Meyn ConsultingOct 31, 1993 2:06 PM
Hy Rob, you can use of '\p' (for password) and '\u' (for username) in so called command sequences, you can define one function key to send \u\r\p\r (username and password, separated by CRs) to answer the CompuServe login sequence. To do this, you must define a phone-book entry for CompuServe, and set username and password there. Even better would be an ARexx script to log into CompuServe (I use one). Look at the supplied demo AutoLogin.term (in the Term:ARexx/ directory), even if you can't program ARexx (like me <g>), the script is easy to understand and to modify. Look into the termRexx documentation for the syntax of the commands. Markus
#120358From: Rob StantonOct 31, 1993 5:26 PM
Thanks, I am not sure that I have the Autolog demo but I am trying to figure out how to use the Macro (AREXX) to auto login. -Rob-