#Release 11 c2 (386) hang

3 messages in this thread
#33763From: Ray ShayFeb 19, 1992 7:24 PM
I client of mine recently upgraded from release 10 (DOS 286) to release 11 c2 (DOS 386) and today I was helping him install the upgrade. We have a problem getting the new software to work on his Epson Equity 386/20 with 2 MB RAM, 20 MB free disk space after the install, MS-DOS 3.3. The system hangs after the "Successful Login" message. Once it didn't even get that far – it crashed upon loading with the message "Fatal Error: FMTOUT 1". Release 10 still works. No hardware or other software changes were made. We have a Northway 386SX in the same office so we tried loading it there and it DOES work. Any ideas?
#33773From: CSA/CAFeb 19, 1992 8:40 PM
Ray, FMOUT error indicates a problem with the math co-processor. Be sure it is firmly seated and the motherboard jumpered or BIOS informed correctly. However, it is possible you receive the problem because of a low memory condition. AutoCAD rel 11-386 really needs 4M to be happy – 2M is probably the bare minimum for the program to even load (not necessarily operate), and you may have other things stealing some of the 2M anyway. Kevin Krell – Computer Support Associates
#34516From: Ray ShayFeb 24, 1992 7:50 PM
The coprocessor was firmly seated and the bios did recognize it. I increase RAM to 4 MB with no luck. I tried a plain vanilla boot-up with no autoexec.bat and only files=40, buffers=20 in config.sys with no change in symptoms. I tried DOS 5.0 without anything load high but no luck. I tried using the older version of the DOS Extender by running through the OLDDX procedure but no luck. I then tried it on a Espon 386/20 in MY office and the same problem occurred. The processor chip has A80386DX-20 on it. Is this the same as the B-step problem chips which have A80386-20 on them?