#50544From: Kelly JordanJan 24, 1987 12:21 PM
HELP!! I can't UpLoad to CIS. First of all, I have no problems downloading. I am in Canada. I call an 800 number datapac port. This port gets me to iNet 2000, a Telecom Canada service. From here I can get to CIS, thru datapac, then I imagine thru tymnet. I do the ^P PROF <ret> SET 2:1 <ret> <ret> stuff okay. Using two different programs. Using StarTerm 3.01, set up 8 bits, CRC Xmodem, relaxed timing, no stripping, after a couple of blocks are sent the upload box seems to disappear and I haven't the slightest idea what kind of mode the terminal program is in. It should say Xmodem transfer Aborted, but it didn't. (works very good for downloads as long as I don't have any errors). Using VT-100 V2.4 from here also. It takes forever. Have it sent to image transfer, then choose xmodem upload. This program must have been sending each block up to 5 times in a row before it gets a response out of CIS. I swear that it must have taken me 5 minutes to upload 5 blocks, so called it quits on the transfer. I know CIS time is free, but Datapac and iNet are not, and together are about the same as CIS fees. I can't use this terminal program for downloading because its timing isn't relaxed enough. I was trying to upload this morning around 10AM Eastern time and the system didn't seem slow. Any help would be appreciated, as I would like to upload my printer drivers and don't really want to try another terminal program until NovaComm is available. Kelly
#50562From: John DraperJan 24, 1987 2:06 PM
Kelly, I gather the string to set the parameters in your last message was a typo, and that you really meant ^P PROF 3 <ret> Another possible source of your problem _might_ be (how's that for definite?) the escape character that gets you back to iNET. I think it defaults to a backslash (\), and is settable. I remember changing mine, but I don't remember what I changed it to. I will be in Toronto all next week, and if you can get down there at all, I would be happy to give you Aterm (or any other stuff you might want out of our library). If I remember correctly you aren't too far from Barrie?? Regards, Larry.
#50594From: Kelly JordanJan 24, 1987 6:24 PM
Larry, I thought I said ^P PROF 3 <ret> SET 2:1 <ret> <ret> Maybe I shouldn't do the SET bit, since your datapac.hlp file says it turns echo back on. Is this echo only for when doing the datapac commands, or does it effect CIS? I can't see it being my iNet escape sequence, since I made it a few characters longer, actually three \ in a row and I don't think there are much odds in getting that in any uploads, though possible. Pretty sure not iNet getting in the way. Barrie – I am about as far from there as I am from TO. Must be at least 500 miles from here to TO, I think the actual driving distance is much more, so I guess we can assume an eye ball is out of the question!! I am in Marathon, which is about half way between Thunder Bay and Sault St. Marie. Thunder Bay is at least three hours driving, the Soo four (never been there yet). When I go to Thunder Bay, I always (so far) have gone there, do my business, and am back the same day! I have one thing left to try, and that is my good old SeXy-64 and the term pgm I got with the 1670 modem. Will I just tried using the SeXy-64 using both B and XModem (the vt100 program does have a problem on xmodem send – every block had to be sent 5 times when sending it to the 64) XModem timed out, as CIS didn't seem to respond after the 9th block sent. B sent two blocks (maybe three) then seemed to just sit there waiting for CIS to respond again. Again I will try it in the morning, but at this time, I gotta say the problem is CIS with the 64. 73, Kelly