#48512From: Steve BrightmanOct 16, 1995 9:16 PM
Malcolm, about GPFax. I assume you have checked the autoanswer box on the options screen ? Also do not try and set autoanswer on the modem throught the init string (found in tooltypes in the GPFax icon), let GPFax do it for you. Also don't try and edit the init string from within the program (under environment if I recall correctly), it won't keep after you exit the program. Good luck, Steve Daring to be different – Amiga on the Internet – Lotus on the Interstate
#48515From: Malcolm BrennerOct 16, 1995 11:58 PM
Dear Steve, yes I checked-on the autoanswer box. I can receive manually just fine but not in autoanswer mode, which makes it a bit difficult. I also wonder how one is supposed to specify the number of rings before the machine picks up. I have queried Supra about this but aside from telling me to click the autoanswer box on and everything would be cool and fruity they haven't responded. Which pisses me off as I paid enough for this damn modem. Is this likely to be a software problem or a hardware problem? I know there are supposed to be some adjustments to make in the modem but I dare not try without understanding what I'm getting into. Any suggestions you can give would be helpful. Thanks, Malcolm
#48567From: Steve BrightmanOct 19, 1995 9:32 PM
Malcolm, I'm not sure I can be of much help 'cos I don't know Supra modems, but just in case it applies I can tell you about how my USR does it ! There is a DIP switch for auto answer on the modem. If Autoanswer is disabled this could be the problem. There is also an S register (command ATSr=n) which affects autoanswer. In my case its register 0 so r=o. The value for n determines the number of rings, with 0 disabling auto answer. Try looking in your manual for something similar. This setting should be made for you by GPFax according to the number of rings you enter on the Environment screen. Now look in your GPFax icon's tooltypes (or under init string on the environment screen) and see if there is something like that in there. Hopefully some Supra expert can jump in and help. BTW, my manual says the init string for Supra is simply AT&F2E0. I assume you installed GPFax for Class 2 modems (which is what you should have for Supra). Good luck, Steve Daring to be different – Amiga on the Internet – Lotus on the Interstate