#85569From: Darrell K. HanningNov 10, 1993 4:01 PM
I have a user in my company with a Mac IIFX (System 7.1) and a Panasonic LF-5010. She's using Panasonic LM-D501W (940MB) cartridges with the drive, and Corel SCSI v1.00 (June 93). For cartridges initialized with the old version of Corel WORM driver, the SCSI extension works fine, but we can't seem to initialize a new cartridge. MOUNT and VERIFY show up on the Tools menu, but the cartridge won't mount when we try, and INITIALIZE is greyed out. When I run Diagnose, I get an error. I just want to know if I've actually run across a bad WORM cartridge (the first in my experience), or if I'm missing something, or if the driver needs to be (yet again) updated. (We've had to update the last three times we changed the Macintosh system software.)
#85722From: Bryan ShearerNov 11, 1993 10:50 AM
Darrell, The cartridge cannot be initialized while it is mounted. Dismount the cartridge and please try again. The Panasonic drive has been certified with SCSI version 1.0 for MAC. I hope this helps. Laszlo
#86459From: Darrell K. HanningNov 15, 1993 2:41 PM
<<The cartridge cannot be initialized while it is mounted.>> OK; "INITIALIZATION" is not available (grayed out), when the cartridge is inserted. MOUNT and VERIFY are. MOUNT results in an (unrealistically) immediate return that the cartridge is mounted, and VERIFY gives an (equally unrealistic) immediate return of 0 errors found on cartridge. DEVICE/DIAGNOSE repeatedly returns "Unable to query drive for capacity. Sense key: 3H (Medium failure)". When I perform a Device Status with the unformatted cartridge inserted, I get "Not Available" for all the cartridge status indicators. The firmware revision for the drive is 2.02, if that's worth anything. Any other suggestions?
#86651From: Bryan ShearerNov 16, 1993 8:44 AM
Darrell, Just to recap a few things. If you are using system 7.0 or higher, you must be using CorelDRIVER for MAC version 4.0.3 or CorelSCSI for MAC. The medium error is indicating that the drive is having problems reading the cartridge. Ensure that the drive and the cartrdige are well cleaned. Use only manufacturer prescribed cleaning kits. Ensure that both are cleaned. I have seen instances where if the lens was dusty a specific cartridge could not be formatted. If the cartridges are new you can pretty much eliminate tham as being dusty (although a quick slide of the media door will prove that). Try increasing the bad sector tolerance for the manual mount to 50. At each attempt, use the drive status option to record the error that the drive is returning to our drivers. I hope this helps. Laszlo