#196604 Matrox Max 96MB Ram Message #196993
> James, I don't have the Matrox card but I experienced a simular problem with my ATI Ultra Graphics Pro during a RAM upgrade. The fix was setting my video memory above my physical RAM. There is a nice little utility with the Mach32 drivers that allowed me to define…
#Lines in Editor Message #196992
Help, All of a sudden I have periodic "spurious?" lines running across the viewports in the Editor and the Keyframer. The lines are not signal interference of any kind. They seem to be generated from the meshes themselves. They appear in any number of situations such as after a bolean…
From: Randy Jackson Autodesk Multimedia Forum · Take 5/Want Ads October 25, 1995 10:12 AM
I just installed a new Rose Electronics "ServeView" Keyboard Controlled Switcher. I am impressed with the quality of this product, the documentation is excellent and installation is a breeze. I work on four computers at the same time and desk space became an increasing issue. Another reason I tried out…
#193606 #Windows95 Message #193771
Brent, You bet. Randy
#193047 #Windows95 Message #193373
Brent, I stumbled across this process for using 3D Studio and 95 on the same machine. It is the only way that works for me, ( that isn't to say there are not other /better ways) we have used this process on all of our machines with no problems so…
#193212 Par and NT Message #193247
From: Randy Jackson Autodesk Multimedia Forum · Hware/OpSys/video September 29, 1995 11:19 PM
Kevin, Thank you. I'm on my way right now. Randy PS We enjoy and learn from your contributions to this forum. Thanks!
#Par and NT Message #193199
From: Randy Jackson Autodesk Multimedia Forum · Hware/OpSys/video September 29, 1995 4:51 PM
Dave, I've been trying to find the 1.37 NT drivers for the PAR. I cannot access the DPS ftp site because I don't have a password. This is discouraging particularly because I'm a dealer for DPS. Called DPS today and the said the drivers are on their BBS. If they…
Lyle, I find it very useful to run the PAR from WFW 3.11. I also shell from 3D Studio to the PAR. This saves time when I need to preview what an image(s) " really" looks like on the TV screen. Anything that saves time in the "Tweaking Process" is…
David, I have to second your application of a fan to the open insides of the computer. I've had a couple of crashes with the PAR\ 2 Micropolis 2217A's but since I opened the tower case and directed a 10 inch fan at it no problems. We use the PAR…
Peter, I also run a Gateway2000 486- 66, 40M-RAM w/ ATI Ultra Graphics Pro. I use ATI Video drivers in Windows at 1024 x 768 60 some thousand colors and all is fine. I've rendered 420 frames at 756 x 480 seq. .tgas with KPT filtering (Gradient Designer " What…
Page Fault/raytrace Message #135733
From: Randy Jackson Autodesk Multimedia Forum · Hware/OpSys/video November 13, 1994 11:30 PM
Hi Jonas, I am following up on this request for help I submitted from a couple of weeks ago. The solution was reloading 3DS with new disks, his original disks were corruped. I quess this weird thing of massive paging only when he rendered with more than one spotlight with…
#Page Fault/raytrace Message #130723
Hi Jonas, The client has 16 meg on the notebook and 24 meg on the tower. The last time I spoke with him, Friday 10/21, he said that normal rendering was now starting to page and that on the 24 meg computer he can't remember that happening before. I told…
#Page Fault/raytrace Message #130184
>>A client of ours recieves a page fault error and 3DSR3 shuts down completely, (this means that he ends up at the DOS prompt and 3DS is no longer running). This only happens when he renders with more than one spotlight with raytrace. !?! This happens on two different computers.…
#130034 Page Fault/raytrace Message #130067
Thanks Jonas, I will call the fellow in the morning and have him send a copy of his version of stripped.
Hi Jeff, I'm going to jump in here to sugest a solution to the hardware lock problem, some of our machines have 5 dongles after bending a port one of my clients brought a little box over to the studio that will hold up to 6 locks and can be…
#Page Fault/raytrace Message #129961
Hi Everyone, A client of ours recieves a page fault error and 3DSR3 shuts down completely, (this means that he ends up at the DOS prompt and 3DS is no longer running). This only happens when he renders with more than one spotlight with raytrace. !?! This happens on two…
From: Randy Jackson Autodesk Multimedia Forum · Hware/OpSys/video September 22, 1994 12:46 AM
I left the block limit set very high while messing around to see what effect it had, if any, on image quality. I hadn't noticed any difference so I left it. I was working on deadline for a local TV spot. We had to call DPS to find out why…
Network Rendering/PAR Message #112767
Hello Everyone, We have been hearing references to network rendering to the PAR over the last couple months and for life of us we cannot figure out how this could be done. We have 4 workstations and a file server on a Novell 3.12 LAN. Are we misinterpreting what is…
Cardinal SNAPplus Desktop Video Adaptor For Sale Purchsed to learn for client support, used 10 Hours. Complete. PC Compatible, Single 16-bit ISA Slot, Video-in, Video-Out, VGA Connectors Video-In/Out: RGB, S-Video, NTSC, PAL Connector for PC/VCR, Special Video Device Control Video Digitization >Real Time >Genlock >Software Controled Hue, Saturation, Contrast >Up…
#108159 #DPS_PAR Message #108796
>>when i record animations or stills with smooth gradations, the images on the par side look more like 16 bit or even 8 bit images. a lot of color banding and dittering.i have tried q and block size settings but i cant get smooth gradations and cant get rid of…
#108529 #Raytrace for 3DS Message #108795
Michael, We are also very interested in beta testing your 3DS3/Ray Tracing program. ComWorks provides animation, interactive training and maintenance services to manufacturing and educational institutions. We are also an authorized Autodesk Dealer & Training Center. Thank you for your time, Randy Jackson, President ComWorks Communications, Inc. 539 Russell Avenue…
#108159 #DPS_PAR Message #108794
>>when i record animations or stills with smooth gradations, the images on the par side look more like 16 bit or even 8 bit images. a lot of color banding and dittering.i have tried q and block size settings but i cant get smooth gradations and cant get rid of…
#108227 viperpci/viberant Message #108439
>> does your upper left viewport frequently not redraw with the others, as in returning from a render screen?
#107626 Best COM Prog for CG? Message #108158
We use PROCOM PLUS from Data Storm. Somewhere around $90.00 for the DOS version. Works fine through an icon in windows. Zmodem works great! Good luck.
#108031 #DPS_PAR Message #108151
>>i just installed a PAR_DPS HD recorder and i am speechless. it is unbelievable. wooowwww!!!
#108020 Using Autocad images Message #108142
Hi Tomas, Have you or your brother looked into Autodesk's AutoVision. You can check it out at your local Autodesk Multimedia dealer. Good Luck, Randy
Congratulations Greg & Susan!
#106427 3dstuio cd rom Message #106554
William, If you determine what the problem is please let me know. I'm checking the drivers as Nik suggested. I may have different DOS versions loaded on different computers. This feels real familar and this does not happen on all my computers. !?!
#105947 3dstuio cd rom Message #106210
Hi William, Sorry to butt in here but we have the same problem sometimes. Havn't really looked into the cause but we just leave a disk in the cd drive at boot-up and that irritating problem of manually addressing the drive went away for us. Hope the band aid helps…
Don, Thank you very much. We have made some adjustments to the wiring confiuration and things have improved considerably. As humiliating as this is I'm going to post what we were doing here for all to see. We were using a Y-type RCA adaptor cord to split the signal to…
#104671 Render RES switching Message #104677
Thank You David. Rendering to NULL did the trick. It took care of the problem I posted to the Hware\Opsys\Video section also. We design and install CATV systems and have run into some pretty strange magnetic induction effects and I was hoping that this wasn't one of them. (See-PAR,TARGA NTSC…
Thanks John, I enjoy reading your responses in this forum and appreciate your quick response. The problem is solved and I will paste the solution below. It was solved in the 3DS section under" Render Switching". I thought these two problems were separate and probably are but rendering to NULL…
#104521 Locked off the Forum Message #104664
Cesar, I've sent messages and about 50% of them never make it to the forum. I just chalked it up to unknown cicumstances. But it does get irritating when I havn't had enough sleep. By the way I can't think of what SW means, what is it?
#Render RES switching Message #104661
I forgot to add this to my earlier request for help concerning the PAR in the Hware/OpSys/Video section under" PAR\TARGA NTSC Distortion" but I think this one is more of a 3DS3 situation so I'm sending it here. We have the render resolution set in 3DS3 to 752×480, aspect at…
Hello to all, We 've had our new PAR\TCBIV for about a week now and it is fantastic! It is installed in a Gateway2000 4DX2-66V, 32meg RAM, w\ Micrpolis 2217A. My NTSC monitors are a Magnavox combination VCR/13" screen, and a Philips 31" TV. Both are around 1 year old.…
"abnormal termination:page fault." "ATI Graphics board, EMM386" Pardon me for jumping in Nik and Matthias. I didn't get Matthias's last name or ID# so I'm sending this to you Nik in hopes that Matthias might read it. I sent it to the thread but it didn't make it. Thread is…
#104321 Locked off the Forum Message #104407
>I want to know why someone is locking me off the Forum. If I try to enter Messages, nothing or almost nothing comes, while a friend of mine gets hundreds of messages. I am suspicious someone is abusing its prerrogatives. This is perhaps an unqualified and incompetent person who is…
#104052- Problems with ATI Mach64 Message #104400
"abnormal termination:page fault." "ATI Graphics board, EMM386" Nik & Matthias, Good answere Nik! I have the same card and it's great. I believe that the slow boot is due to EMM386. I've experimented a great deal with boot configurations and a stripped configuration is by far the fastest boot. I…
#102380 3D Studio Book Message #102767
/* Also, with regards to architectural applications, would it be easier to construct 3D models in AutoCAD and then import them to 3DS or just do it all in 3DS (given the fact that I'd need to learn one or the other anyway)? */ Hi Steve, We've been spending some…
#97554- NTSC output Message #98725
Hi Stan, I'm your friendly Autodesk Multimedia Dealer in Lexington,KY.. Give us a call at ComWorks Communications, Inc. 539 Russell Avenue Lexington, KY. 40508-1952 606-254-1671 fax 606-281-6795 We would be delighted to assist you with any system design or integration questions. (Never a charge for our friends in education!) If…